Site Specifications
SS2616-1 – 23NOV99
3
Section 1: Site Specifications
Space Requirements
Dimensions and Weight (Uncrated)
Site Access:
Doorways to the site should be 91centimetres (36 inches) wide, or larger. The front and rear PRINTER FRAME
DOORS, SHEET TRANSPORT MODULE DOORS, and the OPERATOR CONTROL PANEL (OCP) must be
removed to move the PRINTER through a 36 inch doorway.
Minimum acceptable door size is 71.2 centimetres (28 inches). The enclosures, covers, and subassemblies for the
PAPER SUPPLY MODULE, the KNIFE AND SHEET TRANSPORT MODULE, and the TAKE-UP MODULE†
must be removed to move the PRINTER through a 28 inch doorway.
† Roll-to-roll system only.
Operator and Service Access:
When fully assembled, the system requires a minimum of 91 cm (36 in.) on each side to allow access for service and
operator maintenance.
Floor:
The system should be installed on a smooth, hard, and level floor surface. Floor pitch should not exceed 1 inch in 5
feet.
Operating Environment
The unit to be installed is an Insulation Catagory Type II machine and operates in a Pollution Degree 2 environment
in accordance with IEC 664 ( Normal Office Environment ).
* Room temperature changes of more than 5 degrees during operation will require recalibration of the PRINTER.
**Although the PRINTER and PROCESSOR operate in normal room lighting, access to a darkroom is required for
loading paper into cassettes.
Width
Length
Weight
Printer:
102 cm (40 in.)
149 cm (58.5 in.)
420 kg (925 lbs)
429 kg (945 lbs) with
paper.
Processor:
87.6 cm (34.5 in.)
130 cm (51 in.)
without removable print
rack.
198 cm (78 in.) with print
rack installed.
172 kg (380 lbs)
312 kg (471 lbs) with
processing chemicals.
Roll-to-roll Printer:
102 cm (40 in.)
189 cm (74.5 in.)
510 kg (1125 lbs)
519 kg (1145 lbs) with
paper.
Description
Specification
Temperature*
15.5-26.6°C (60-80° F) for unplumbed
systems15.5-30° C (60-86° F) for plumbed
systems
Relative Humidity
15-76%
Altitude
0-2000 metres (6562 feet)
Lighting
maximum of 325 lux **
(30.2 foot-candles)