Home Auto: KHV-444/454/446/456

- Do not insert any metallic materials into the inside of fuse cover. It may cause electric shock.

- Do not close ear to speaker. Abrupt call or signal may give harmful effects on user's hearing.

- After turning power on and off, check again that input contents are saved correctly. Otherwise, data may be missed when auto-signal mode operates.

- Use a standard detector. Non-standardized detectors are likely to cause fire due to excessive voltage or current.

- Please install motion detector at a place easily detect the motions of subjects. When detector is installed at a wrong place or obstacles block the front 

side of detector, it cannot work well.

- When setting night guard mode, be sure that detector should be connected well.

- Sufficiently charge the battery of wireless handset before using it. Be careful that children should not throw battery. Be sure to close battery cover 

(When children throw or disassemble battery, it may cause serious accidents).

- Be careful that the polarity of the product matches to that of guardroom communication cable. When polarity is reversed, it may cause abnormal 

operations of the product or apartment system as a whole.

4-Line Related Products: KVM-604, 624, 524RG, 524G, 524GS, 520, KCV-346/356

- In wiring work, be careful that wirings should keep away from the wall-mounting pegs or other furniture at regular interval. Contact of wiring with 

wall-mounting pegs, etc. may cause short-circuit, electric shock and fire (it is applied to all products with wall-mounting pegs).

- Use the prescribed standard wirings. Non-standardized wirings may give adverse effects on operation of product 

(it is applied to both video phone and CCTV).

CCTV Camera

- Do not install at noisy places.

- Do not install at the place exposed to electromagnetic waves. 

Excessive electromagnetic waves may cause continuous noise on screen and mechanical troubles.

- When installing camera outdoor, please put it in the outdoor case. Otherwise, when it rains, the camera may be broken or operate incorrectly.  

- Install the product at well-ventilated places.

- Do not use the product for medical or military uses.

- Do not install the product at humid places. It may cause reduction of the product's durability as well as fire and electric shock.

- When lens is stained with alien substances, clean it with soft cloth to prevent the damages on it.

- Install the product out of reach of children.

System for Multi-unit Housing

- In installation, be careful that other wiring or metallic substances should not contact to the system for multi-unit housing. 

- In installation, be careful that alien substances should not go into the system.

- Before installation, be fully aware of wiring specifications of each model.

- In installation, be sure that the length and dimension of wiring meet the requirement prescribed in installation manual.

- Excessive strength and external shock may cause mechanical breakdowns of equipment.

- Do not arbitrarily open the case of the product 

(When user opens the case arbitrarily, KOCOM may reject to provide A/S service).

Lobby Phone: KLP-(100, 104, 108, 112), KLP-(P100, P104, P108, P112), KDP-(100, 104, 108, 112),
KLP-(C100, C104, C108, C112)

- A stroke of lighting or strong shock may give fatal and adverse effects on system. Thus, do not fail to ground the system.

- For registration of household password, please refer to user manual of the concerned product (it is applied to ten-key lobby phone products 

[KLP-100, KLP-P100, KDP-100 and KLP-C100]).

Relay : KVS-104P

- A relay can support up to four households.

- In the case of over four householders, additional relays are needed.

Video Amplifier : KHU-102P

- In installation, follow the specification for Video in/output.

Video Phone

- In assembling the product, be careful that wall-mounting pegs should not contact with wirings.

- In connection of cables, strip its insulation off as much as necessary (Excessive stripping off its insulation may cause short circuit).

- Be careful that signal cables should not be wired with A/C wiring (it may cause poor display quality).

- Do not drop handset (its damage or short-circuit due to drop may make communication impossible).

- When connecting wires to terminals, use standard screwdriver (otherwise, screws may loosen, which will result in disconnection of wiring).

- Do not clean CRT screen with wet towel or cloth. When water penetrates into the product, it may cause short-circuit. 

Do not fail to clean it with dry towel or soft cloth.

- Do not install camera at the place where water penetrates or leaks. Penetration or leakage of water may cause electric shock or short circuit.

Safety Instructions, Warnings, and Cautions of Each System

-  This equipment is electronically precision equipment, so do not arbitrarily disassemble it.
-  In installation of the product, do not fail to follow the specifications (specifications offered by KOCOM). 
-  Do not touch the product with alien materials (for example, sticker, magnet, opener, metal chopstick, etc.) 

or insert them into the product (it may cause reduction of the product's durability and harmful results to user as well).

- In the rainy season, water is likely to penetrate into the product along the wiring. Thus, U-type finishing is recommended 

as a desirable method of end part finishing.

5

6

Summary of Contents for KC-C60

Page 1: ...ality improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control and inspection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases...

Page 2: ... product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or qualified electrician When replacing old fuse with new one do not directly touch it with bare hands Use insulated tools or contact A S center Cautions Warnings for disposal Read this cautions carefully and ...

Page 3: ...sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can High temperature of equipment may cause fire and electric shock Warnings Warnings Cautions for Use Do not install the product at bathroom or at the place near a washing machine or at other humid places It...

Page 4: ...s should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of each model In installation be sure that the length and dimension of wiring meet the requirement prescribed in installation manual Excessive strength and external shock may cause mechanical breakdowns ...

Page 5: ...between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circulation MIC Sending the voice to lobby phone guard phone camera and other equipment connecting to in house line Power LED Communication Button When receiving the call signal from interlocked outside equipment user can communicate with it ...

Page 6: ...ion Bottom base of One hall Box Surface mount Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard height monitor Standard height of monitor is ranged 1 450 1 500 from bottom to the center of monitor screen For installation avoid the places where there is any excessive humidity magnetic force dangerous chemicals direct ray of sun and any places near a h...

Page 7: ...is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone s Lobby Monitoring Function Call Method Communication Method Image Maintenance Time Number of Wiring Dimensions Communication Distance Guaranteed Operation Temperature KC C60 KC MC35 Front Door Camera KIV 212 Monitor KIV D212 Monitor Component Monit...

Page 8: ...ration or poor communication quality please carefully conduct wiring work When connecting a wiring chord to a terminal loosen screw insert the end of the chord into the bottom part of screw and tighten the screw When fixing wiring chord use stapler not to cause damage to the chord When using existing wiring please be cautious not to cause disconnection and short circuit Wiring for multi houses apa...

Page 9: ...oor open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen 2 Monitoring for Camera 2 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen And if pressing the front do...

Page 10: ...ine button to end communication Users can control chime volume by adjusting 3 level volume switch on videophone In all functions call maintenance time is set for 30 seconds After 30 seconds call signal and images return to stand by mode All communications maintains for 3 minutes After 3 minutes communication automatically returns to stand by mode Instructions for Operation Model KLP 100 KLP P100 K...

Page 11: ...D MODE It is compatible with the existing units ID is available with 1 63 1000 1963 2000 2963 3000 3963 In this case DIP SWITCH 1 3 4 7 8 12 is put to ON the result is 1 4 8 100 200 2 000 2313 the house No 2313 In this case DIP SWITCH 1 9 11 12 is put to ON the result is 1 400 1000 1401 the house No 1401 In this case DIP SWITCH 1 2 7 is put to ON the result is 1 2 100 103 the house No 103 In this ...

Page 12: ... DIP SWITCH 2 7 11 12 is put to ON the result is 2 100 1000 2000 3102 the house No 3102 ex8 ex9 ex10 This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certified card The RF card touch area In this ca...

Page 13: ...is available to set from No 1 1599 1 DIP SW 1 4 it is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 2 DIP SW 5 8 is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 3 DIP SW 9 12 is available by 15 the sum of 1248 100 1 500 10 90 1 9 800 400 200 100 80 40 2...

Page 14: ... 3 If interphone and video phone are used as Sub phone all of DIP SWITCH should be OFF 4 Don t try to set by force Otherwise errors can occur This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certifi...