background image

KIV-212, KIV-D212 User

s Manual for Operation and Installation 

Communication and monitoring by front door camera. 

Interactive call and communication between house and guardroom. 

Inner line call and communication within the house. 

Communication with lobby phone and door open function.

Monitoring of lobby.

For both single house and multi house (Apartments). 

KIV-212 : AC type

KIV-D212 : DC type

COLOR HANDS-FREE 

VIDEO PHONE

Thank you very much 
for purchasing KOCOM 
video doorphone. 
please read this manual 
thoroughly to ensure 
correct usage, before 
operating. 

KIV-212 / KIV-D212    08.03

This manual is based on the date as shown in the right and specifications 
are subject to change without notice for quality improvement.

PRODUCT

MODEL 

DATE PURCHASED

WARRANTY PERIOD

AGENCY ADDRESS

KOCOM Warranties the original purchaser of this product as follows.

1) This product is produced under strict quality control and inspection procedures.

2) If this product breaks down during proper use as a result of product defect, KOCOM  

will repair it within one year from date  of purchase free of charge.

3) The following cases will be subject to charge, even during warranty period:

a. Breakdown during transport, or through careless treatment,  by consumer.

b. Breakdown cause by unauthorized repair, or system  modification.

c. Breakdown caused by natural disaster or power disorder. 

Warranty 

Warranty Card   

To receive after-Sale service, have the following ready 
when you contact our branches.

1. Name of the product.

2. Model number of the product.

3. The area of problem.

4. Phone number and address at     

which you can be contacted.

Summary of Contents for KC-C60

Page 1: ...ality improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control and inspection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases...

Page 2: ... product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or qualified electrician When replacing old fuse with new one do not directly touch it with bare hands Use insulated tools or contact A S center Cautions Warnings for disposal Read this cautions carefully and ...

Page 3: ...sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can High temperature of equipment may cause fire and electric shock Warnings Warnings Cautions for Use Do not install the product at bathroom or at the place near a washing machine or at other humid places It...

Page 4: ...s should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of each model In installation be sure that the length and dimension of wiring meet the requirement prescribed in installation manual Excessive strength and external shock may cause mechanical breakdowns ...

Page 5: ...between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circulation MIC Sending the voice to lobby phone guard phone camera and other equipment connecting to in house line Power LED Communication Button When receiving the call signal from interlocked outside equipment user can communicate with it ...

Page 6: ...ion Bottom base of One hall Box Surface mount Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard height monitor Standard height of monitor is ranged 1 450 1 500 from bottom to the center of monitor screen For installation avoid the places where there is any excessive humidity magnetic force dangerous chemicals direct ray of sun and any places near a h...

Page 7: ...is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone s Lobby Monitoring Function Call Method Communication Method Image Maintenance Time Number of Wiring Dimensions Communication Distance Guaranteed Operation Temperature KC C60 KC MC35 Front Door Camera KIV 212 Monitor KIV D212 Monitor Component Monit...

Page 8: ...ration or poor communication quality please carefully conduct wiring work When connecting a wiring chord to a terminal loosen screw insert the end of the chord into the bottom part of screw and tighten the screw When fixing wiring chord use stapler not to cause damage to the chord When using existing wiring please be cautious not to cause disconnection and short circuit Wiring for multi houses apa...

Page 9: ...oor open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen 2 Monitoring for Camera 2 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen And if pressing the front do...

Page 10: ...ine button to end communication Users can control chime volume by adjusting 3 level volume switch on videophone In all functions call maintenance time is set for 30 seconds After 30 seconds call signal and images return to stand by mode All communications maintains for 3 minutes After 3 minutes communication automatically returns to stand by mode Instructions for Operation Model KLP 100 KLP P100 K...

Page 11: ...D MODE It is compatible with the existing units ID is available with 1 63 1000 1963 2000 2963 3000 3963 In this case DIP SWITCH 1 3 4 7 8 12 is put to ON the result is 1 4 8 100 200 2 000 2313 the house No 2313 In this case DIP SWITCH 1 9 11 12 is put to ON the result is 1 400 1000 1401 the house No 1401 In this case DIP SWITCH 1 2 7 is put to ON the result is 1 2 100 103 the house No 103 In this ...

Page 12: ... DIP SWITCH 2 7 11 12 is put to ON the result is 2 100 1000 2000 3102 the house No 3102 ex8 ex9 ex10 This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certified card The RF card touch area In this ca...

Page 13: ...is available to set from No 1 1599 1 DIP SW 1 4 it is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 2 DIP SW 5 8 is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 3 DIP SW 9 12 is available by 15 the sum of 1248 100 1 500 10 90 1 9 800 400 200 100 80 40 2...

Page 14: ... 3 If interphone and video phone are used as Sub phone all of DIP SWITCH should be OFF 4 Don t try to set by force Otherwise errors can occur This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certifi...