ZOE
Page 30
ZOE K04/0718
9.7.1
Pulse output / Volume
The "pulse volume" parameter is defined as the volumetric amount for the output of a
pulse at the output; the unit is in accordance with [amount of volume / pulse]. The
familiar Pulse rate [pulses / unit volume] corresponds to the reciprocal of the pulse
volume.
Example: Required pulse rate at output 10 Pulse/Liter => Pulse Volume = 1/Pulse rate
= 1/10 L = 0.1 L
9.7.2
Pulse output / Unit
The volume set unit is the input unit for the parameter "Pulse volume". User can also
set a user defined unit which will be given in “Liter”. e.g.:
Unit: user = 10 [Liter], pulse volume = 2 [user]
In this case the pulse will be generated after 2*10 = 20 Liters
9.7.3
Pulse output / Width
The pulse width of pulse output is flexibly adjustable from 1 to 20000 ms.
9.8 User service
Reset function and password activation are available for user in user service menu.
Together with the activation of a user password, the access to menu for the user can
be locked by a master user.
9.8.1
User service / Change password
The default administrator user password is set to "00000", the user functions are thus
freely accessible. If the user's password has been changed from "00000", password
request will be generated on next entry to User menu.
If the default password has been forgotten or misplaced, the master password can be
requested from KOBOLD.
9.8.2
User service / Reset
By activating this function, the user can reset the device to factory settings. All user
settings will be lost and the device will be reset to the factory settings.
9.9 Factory service
The factory service function is password protected and is not available for the user.
9.10 Information
9.10.1 Status
The partial and accumulated totalisers can be seen by the user through this menu
function.
9.10.2 Firmware
version
This menu function shows the user the installed firmware version and revision. The
information about firmware version can also be seen when the electronics is first
switched on.