7. Electrical Connection
Attention!
Incorrect wiring will lead to damage of the unit’s electronics.
7.1 Connection for MAN-LD
Make sure that the supply wires are de-energized.
Plug in the system according to the connecting diagrams.
Power supply conductor (area of cross-section) min. 0.34 mm².
Pin assignment
Contact-No.
MAN-LD1...
MAN-LD2...
MAN-LD3...
Cable colour
1
+V
S
/ 24 V
DC
+V
S
/ 24 V
DC
+V
S
/ 24 V
DC
brown
2
N/O contact
white
3
GND
GND
GND
blue
4
analogue output
4-20 mA
black
5
N/O contact
grey
Plug M12x1
5-core Cable
Kabel adern
fa rbcod ier t
Connection example
The N/O contact is a potential-free relay which
can be operated within its maximum switching
values.
The shown assignment of 12 V
DC
(connection 2)
and GND (connection 5) is only to be
understood as an example.
2
1
4
5
3
View on plug
contacts
Cable wires
l
colour-coded
2
1
4
5
3
X
GND
e.g. GND
e.g. 12 V
DC
+24 V
DC