MAN-SD/-LD
MAN-SD/-LD K11/0422
Seite 17
13. Order Codes
(Order details:
MAN-SD1S 5 AD 0
)
Version
Power
supply
Model
Mechanical
connection*
Measuring range*
Electrical
connection
Standard
9 V Batterie
MAN-SD1S...
5
= G 1/4 AG
6
= G 1/2 AG
R
= 1/4 NPT AG
S
= 1/2 NPT AG
AD
= -1...0 bar
A1
= -1...+1,5 bar
A2
= -1...+3 bar
A3
= -1...+5 bar
A4
= -1...+9 bar
A5
= -1...+15 bar
B1
= 0...+0,6 bar
B2
= 0...+1 bar
B3
= 0...+1,6 bar
B4
= 0...+2,5 bar
B5
= 0...+4 bar
B6
= 0...+6 bar
B7
= 0...+10 bar
B8
= 0...+16 bar
B9
= 0...+25 bar
B0
= 0...+40 bar
C1
= 0...+60 bar
C2
= 0...+100 bar
C3
= 0...+160 bar
C4
= 0...+250 bar
C5
= 0...+400 bar
C6
= 0...+600 bar
C7
= 0...+700 bar
D7
= 0...+1000 bar
D8
= 0...+1600 bar
0
= none
Relay output
9 V Batterie
MAN-SD2S...
S =
connector
M12x1
K
=0.5 m
cable
Output 0-2 V
9 V Batterie
MAN-SD3S...
Standard
24 VDC
MAN-LD1S...
S
=
connector
M12 x 1
Relay output
24 VDC
MAN-LD2S...
Output
4-20 mA
24 VDC
MAN-LD3S...
*Please specify other connections (7/8 UNF for refrigeration technology, M16, etc.) and special measuring
ranges in plain text.
Measuring ranges up to 1000 bar are preferable completed with process connections G1/2 or
M16x1.5 female thread!
Order details
(continued)
Automatic
switch-off times
Other options
(please specify in plain text)
without
= continuous operation
(standard except
MAN-SD1)
B
= 4 minutes
C
= 8 minutes
(standard MAN-SD1)
D
= 16 minutes
E
= 32 minutes
F
= 64 minutes
display in mbar, PSI, hPa etc.
conversion rate 1-10 pro sec.