MAN-SD/-LD 

MAN-SD/-LD K11/0422 

 

Seite 3 

2. Note 

Please  read  these  operating  instructions  before  unpacking  and  putting  the  unit 
into operation. Follow the instructions precisely as described herein.  
The instruction manuals on our website www.kobold.com are always for currently 
manufactured version of our products. Due to technical changes, the instruction 
manuals available online may not always correspond to the product version you 
have  purchased.  If  you  need  an  instruction  manual  that  corresponds  to  the 
purchased  product  version,  you  can  request  it  from  us  free  of  charge  by  email 
([email protected]) in PDF format, specifying the relevant invoice number and 
serial number. If you wish, the operating instructions can also be sent to you by 
post in paper form against an applicable postage fee.

 

 
The  devices  are  only  to  be  used,  maintained  and  serviced  by  persons  familiar 
with  these  operating  instructions  and  in  accordance  with  local  regulations 
applying to Health & Safety and prevention of accidents.  
 
When used in machines, the measuring unit MAN-LD / MAN-SD should be used 
only when the machines fulfil the EC-machine guidelines. 
 
 
 

3. Instrument Inspection 

Instruments are inspected before shipping and sent out in perfect condition.  
Should damage to a device be visible, we recommend a thorough inspection of 
the  delivery  packaging.  In  case  of  damage,  please  inform  your  parcel  service  / 
forwarding  agent  immediately,  since  they  are  responsible  for  damages  during 
transit. 
 

Scope of delivery: 

The standard delivery includes: 

  Digital Manometer with LCD-Display 

model: MAN-SD / MAN-LD 

  only MAN-SD: 9 V –block battery (IEC 6 LR 61) 

 
 
 

Summary of Contents for MAN-LD Series

Page 1: ...Operating Instructions for Digital Manometer Model MAN SD MAN LD...

Page 2: ...7 8 Function Keys 8 9 Adjustment 9 10 Control Functions 10 10 1 Control function for MAN LD 10 10 2 Control function for MAN SD 12 11 Maintenance 14 11 1 Notice According to the Battery Law 14 12 Tec...

Page 3: ...uctions can also be sent to you by post in paper form against an applicable postage fee The devices are only to be used maintained and serviced by persons familiar with these operating instructions an...

Page 4: ...measuring unit MAN LD MAN SD should be used only when the machines fulfil the EEC machine guidelines 5 Operating Principle The pressure to be measured is sensed by a ceramic sensor and displayed by t...

Page 5: ...sket flat seal or seal ring according to DIN 16258 While threading in the device install on the hexagonal screw AF 24 and not the gauge housing Only use a wrench for mounting If possible after the mec...

Page 6: ...N LD1 MAN LD2 MAN LD3 Cable colour 1 VS 24 VDC VS 24 VDC VS 24 VDC brown 2 N O contact white 3 GND GND GND blue 4 analogue output 4 20 mA black 5 N O contact grey Plug M12x1 5 core CableK a b e l a d...

Page 7: ...ace the 9V block battery in the enclosure and close it with the lid Terminate the connection wires on the plug cable as shown in the illustration below Only with option limit contact or analogue outpu...

Page 8: ...next menu option previous menu option P jump to the function for MAN SD next menu option previous menu option P 1 x press to switch on P 1 x press to switch off P jump to the function Adjustments and...

Page 9: ...point setting on inside battery cover 2 password factory pre set 5 3 peak value memory 4 relay option with settable hysteresis 5 factory pre set switching point on 50 of measuring range Factory pre s...

Page 10: ...ey Note With the switch off of the device the peak value memory is reset P 1xP unit switched on LCD display resetting peak value memory 1234 P 1xP unit switched off peak value memory P last setting ex...

Page 11: ...n password input P password set on 5 factory setting change P access to further menu options relay set point on rising pressure P last switching point setting set sw point on e g 06 50 change P relay...

Page 12: ...unit switched off peak value memory P last setting example setting register max value register min value peak value memory off select cancel P confirm selection and go to next menu option password in...

Page 13: ...change P next menu option password password input P set on 5 factory setting access to further menu options change P last switching point setting relay set point on rising pressure P set sw point on e...

Page 14: ...symbol Cd Hg or Pb of heavy metal for classification as respective contaminant 1 Cd stands for cadmium 2 Hg stands for mercury 3 Pb stands for lead 12 Technical Data Display 4 digit LCD digit height 1...

Page 15: ...PT outer thread range 1000 bar only G 1 2 or 1 2 NPT stainless steel 1 4571 other connections on request Temperature of the medium 30 85 C Ambient temperature 0 60 C Storage temperature 30 80 C Allowe...

Page 16: ...h 17300 h Automatic switch off times 2 64 min auto off can only be set ex works 0 inactive recommended for analogue or switching output Peak value memory MIN or MAX values Reset via keypad MAN LD Pow...

Page 17: ...8 0 1600 bar 0 none Relay output 9 V Batterie MAN SD2S S connector M12x1 K 0 5 m cable Output 0 2 V 9 V Batterie MAN SD3S Standard 24 VDC MAN LD1S S connector M12 x 1 Relay output 24 VDC MAN LD2S Outp...

Page 18: ...MAN SD LD Seite 18 MAN SD LD K11 0422 14 Dimensions MAN SD MAN LD 51 14 74 G1 4A M12 x 1 24 turnable display 3 5 5 24 AF 89 38 2 30 51 14 74 G1 4A turnable 3 5 5 24 AF M12 x 1 89 38...

Page 19: ...N 61326 1 2013 EMC requirements Electrical equipment for measurement control and laboratory use Part 1 General requirements EN 61010 1 2011 Safety requirements for electrical measuring control and lab...

Page 20: ...uidelines are fulfilled 2014 30 EU EMC Directive 2014 68 EU PED Category I Diagram 1 Vessel Gases Group 1 dangerous fluids 2011 65 EU RoHS category 9 2006 66 EC Directive Batteries and Accumulators Ho...

Reviews: