KSM 

KSM K08/0818 

 

page 3 

2. Note 

Please read these operating instructions before unpacking and putting the unit 
into operation. Follow the instructions precisely as described herein.  
The devices are only to be used, maintained and serviced by persons familiar 
with these operating instructions and in accordance with local regulations 
applying to Health & Safety and prevention of accidents.  
 
When used in machines, the measuring unit should be used only when the 
machines fulfil the EC-machine guidelines. 
 
 

PED 2014/68/EU 

In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the 
PED 2014/68/EU no CE mark. 
 

 Pipe 

 

 Table 

Group 1  

dangerous fluids  

Table 9 

 Group 2  

no dangerous fluids  

KSM-x001 – KSM-x010 

Art. 4, § 3 

Art. 4, § 3 

KSM-x020 – KSM-x600  

Kat. I 

Art. 4, § 3 

 
 
 

3. Regulation 

Use 

Any use of the Plastic Flow Meter, model: KSM, which exceeds the 
manufacturer’s specification, may invalidate its warranty. Therefore any resulting 
damage is not the responsibility of the manufacturer. The user assumes all risk 
for such usage.  

Summary of Contents for KSM-**001

Page 1: ...Operating Instructions for Plastic Flow Meter Model KSM...

Page 2: ...anical Connection 4 7 Electrical Connection 5 8 Operation 6 9 Technical Data 7 10 Order Codes 8 11 Maintenance 10 12 Dimensions 11 13 EU Declaration of Conformance 12 Manufactured and sold by Kobold M...

Page 3: ...chines the measuring unit should be used only when the machines fulfil the EC machine guidelines PED 2014 68 EU In acc with Article 4 Paragraph 3 Sound Engineering Practice of the PED 2014 68 EU no CE...

Page 4: ...Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition Should damage to a device be visible we recommend a thorough inspection of the delivery packaging In c...

Page 5: ...lines are disconnected from power Loosen the plug cap holding screw and remove the cap from the switch housing Connect the supply lines inside the plug cap in accordance with the connection diagram op...

Page 6: ...rising flow approx 5 mm above the bottom edge of switch housing Slide the switch housing up or down until the reference edge coincides with the desired switch point scale reading Hysteresis Hysteresi...

Page 7: ...ty 1 Reed contact optional Bistable Reed contact N O on rising flow Max ambient temperature 0 55 C Max power 230 VAC 10 W 12 VA 0 5 A Hysteresis approx 3 12 mm span Protection IP 65 While upgrading a...

Page 8: ...itting K32 glue in connection Da32 PCV P15 PVC G 1 2 IG P20 PVC G 3 4 IG P25 PVC G 1 IG T25 malleable cast iron G 1 IG V32 PVDF Welding sleeve Da32 F25 PVC flange DN 25 R0 without contact R1 1 contact...

Page 9: ...0 bar rel 1 1 bar rel 2 2 bar rel 3 3 bar rel 4 4 bar rel 5 5 bar rel 6 6 bar rel 7 7 bar rel 8 8 bar rel 000 without auxiliary screwed fitting K32 glue in connection Da32 PVC P15 PVC G 1 2 IG P20 PVC...

Page 10: ...cleaning of the unit is recommended Remove the units from the piping with a suitable tool clean the flow meter with a suitable cleaning agent or make use of an ultrasonic bath If using the setpoint sw...

Page 11: ...0 385 432 441 480 385 60 KSM 010 25 R 1 1 2 32 335 341 390 385 432 441 480 385 60 KSM 020 40 R 2 1 4 50 335 341 401 403 467 477 525 403 83 KSM 030 40 R 2 1 4 50 335 341 401 403 467 477 525 403 83 KSM...

Page 12: ...regulation and Laboratory equipment EN 60529 2014 Protection through housing IP Code EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the...