8. Operation

In order to initialise the bistable switching function, it is essential 
that the float activates the contact once in each direction. 

Adjustment of limit-values 

The switch-point can be adjusted to the desired levels by using both red sliders 
as reference points. 

Reference edge for falling flow

: bottom-edge, switch housing  

Reference edge for rising flow

:  approx.  5  mm  above  the  bottom-edge  of  switch 

housing. 
Slide the switch housing up or down until the reference edge coincides with the 
desired switch-point scale reading. 

Hysteresis 

Hysteresis is the difference between the level at which “switch-on” occurs during 
rising flow and the level at which “switch-off” occurs during decreasing flow. The 
hysteresis is approximately 5 mm on the float range. 

Overranging 

With  non-pulsating  flow,  the  maximum  flow  rate  can  be  exceeded.  Only  an 
increase  in  pressure  loss  will  result  (max.  permissible  operating  pressure  must 
not be exceeded!) 

9. Maintenance

If the medium to be measured is clean, the series KSK is virtually maintenance-
free. If deposits form on the inner housing or parts, periodic cleaning of the unit is 
recommended.  Remove  the  units  from  the  piping  with  a  suitable  tool;  clean  the 
flow meter with a suitable cleaning agent or make use of an ultrasonic bath. 

Summary of Contents for KSK

Page 1: ...Operating Instructions for Plastic Flow Meter Model KSK ...

Page 2: ...bistable option 5 7 2 Electronic Contact option 6 8 Operation 7 9 Maintenance 7 10 Technical Information 8 11 Order Codes 9 12 Dimensions 10 13 EU Declaration of Conformance 11 14 UK Declaration of Conformity 12 Manufactured and sold by KOBOLD Instruments Inc 1801 Parkway View Drive Pittsburgh PA 15205 1422 Tel 412 788 2830 Fax 412 788 4980 E Mail info koboldusa com Internet www koboldusa com ...

Page 3: ... these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents When used in machines the measuring unit should be used only when the machines fulfil the EC machine guidelines as per PED 2014 68 EU In acc with Article 4 Paragraph 3 Sound Engineering Practice of the PED 2014 68 EU no CE mark Diagram 6 Pipe Group 1 dangerous fluids 3 Instr...

Page 4: ...lation Remove all transportation safety locks and ensure that no packing material remains within the unit Be sure that the maximum allowable operating pressure and temperature is not exceeded see Technical Data Install the flow meter in the piping system ensure the instrument is under no mechanical stress tension install support bracing if necessary Protect the measuring tube from external damage ...

Page 5: ...rdance with the connection diagram opposite If the set point has not yet been adjusted it may be done at this point see section 8 Operation Set the plug to the socket and fix it with the safety screws Attention The stated electrical parameters of the contact may not be exceeded even for a short period of time For inductive or capacitive loads we recommend the use of contact protection measures res...

Page 6: ...done at this point see section 8 Operation Set the plug to the socket and fix it with the safety screws Attention The stated electrical parameters of the contact may not be exceeded For inductive or capacitive loads we recommend the use of contact protection measures respectively the application of a contact protection relay After connecting the external devices and adjusting the switch housing to...

Page 7: ...cale reading Hysteresis Hysteresis is the difference between the level at which switch on occurs during rising flow and the level at which switch off occurs during decreasing flow The hysteresis is approximately 5 mm on the float range Overranging With non pulsating flow the maximum flow rate can be exceeded Only an increase in pressure loss will result max permissible operating pressure must not ...

Page 8: ...Max operating temp Accuracy class Connection standard KSK 1 and KSK 2 Contacts optional The flow meter can be fitted with either reed contacts or electronic contacts Reed contacts bistable Switching voltage max 130 VAC Breaking capacity max 10 W 10 VA Switching current max 0 5 A Contact resistance 150 m Ohm Insulation resistance 105 Ohm Allowed ambient temperature 0 55 C Protection IP 65 Contact h...

Page 9: ...ter M LPM Water Air Scale See Table 0S 0 PSIG 1S 15 PSIG 2S 30 PSIG 3S 45 PSIG 4S 60 PSIG 5S 75 PSIG 6S 85 PSIG 7S 100 PSIG 8S 115 PSIG 9S 130 PSIG Z 145 PSIG For KSK x015 to x100 K10 PVC 3 8 Glue Socket T10 PVC 3 8 NPT Female 00 Without S0 1 N O Reed SS 2 N O Reed C0 1 N C Reed CC 2 N C Reed E0 1 NPN EE 2 NPN 0 01 0 10 0 07 KSK 1025 KSK 2025 0 02 0 20 0 07 KSK 1050 KSK 2050 0 04 0 44 0 07 KSK 110...

Page 10: ...KSK page 10 KSK 01 0322 12 Dimensions ...

Page 11: ...industrial environments EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements EN 60529 2014 Protection through housing IP Code EN IEC 63000 2018 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Also the following EC guidelines are ful...

Page 12: ...rical equipment for measurement control and laboratory use General requirements BS EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP Code BS EN IEC 63000 2018 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Also the following UK guidelines are fulfilled S I 2016 1091 Electromagnetic Compati...

Reviews: