Kobold KDF-9 Operating Instructions Manual Download Page 17

Operating Instructions KDF-9/KDG-9

 

 

 

Page 17 

 

 

                  KDF-9/KDG-9 K04/0922 

19  Model Code 

Liquids Order Details

 (Example: 

KDF-9291 NV 0 00 0

Measuring 

range water 

[l/h] 

Valve 

seat 

[mm] 

Pressure 

drop 

[mbar] 

Order no. 

stainless 

steel 

Connection 

Gasket 

option 

Wall-instal-

lation 

Contact option 

Miscellaneous op-

tions 

0,02-0,25 

2,8 

KDF-9291...

1)

 

= ¼“ NPT 

= G ¼

4)

   

W

 = hose  

       connector  
       angular, 90°,  
       for 8 mm hose 

= hose  

       connector,  
       straight, for  
       8 mm hose 

Y

 = Special 

V

 = FPM 

T

 = FFKM 

= without 

W

 = with 

00

 = without  

        contactt 
 

with 2 m cable 
M3

 = 1 contact  

          monostable 

N3 

= 1 contact  

         bistable 
 

with  
junction box 
A3

 = 1 contact  

         monostable 

B3

 = 1 contact  

         bistable 

0

 = without 

E

 = differential pres. 

      contr. with 
      constant outlet  
      pressure, valve  
       at input  
       ¼“ NPT, FPM 

= differential pres. 

       contr. with  
       constant inlet  
       pressure, valve  
       at output  
        ¼“ NPT, FPM 
 

= as ‚E‘ however  

      with FFKM  
      instead of FPM 

= as ‚A‘ however 

       with FFKM    
       instead  FPM 

= e.g. without  

       valve,  
       Please specify  

      in writing

0,08-0,7 

2,8 

KDF-9292...

1)

 

0,1-1,0 

2,8 

KDF-9279...

 

0,25-2,5 

2,8 

KDF-9280...

 

0,6-6,3 

2,8 

KDF-9281...

 

1,0-10 

2,8 

KDF-9282...

 

1,5-16 

2,8 

KDF-9283...

 

2,5-25 

2,8 

KDF-9284...

 

4,0-40 

2,8 

KDF-9285...

 

6,0-63 

2,8 

KDF-9286...

 2

)

 

10-100 

2,8 

KDF-9287...

 1)

 

Special 

range 

on re-

quest 

on re-

quest 

KDF-92YY...

 

 

 
Gases Order Details

 (Example: 

KDG-9288 NV 0 00 0

Measuring 

range air 

[Nl/h] 

Valve 

seat 

[mm] 

Pressure 

drop 

[mbar] 

Order no. 

stainless 

steel 

Connection 

Gasket op-

tion 

Wall in-

stalla-

tion

Contact option 

Miscellaneous op-

tions 

2.0-20 

2.8 

KDG-9288...

1)

 

= ¼“ NPT 

= G ¼

4)

   

W

 = hose  

       connector  
       angular, 90°,  
       for 8 mm hose 

= hose  

       connector,  
       straight, for  
       8 mm hose 

Y

 = Special 

V

 = FPM 

T

 = FFKM 

= wit-

hout 

W

 = with 

00

 = without  

        contactt 
 

with 2 m cable 
M3

 = 1 contact  

          monostable 

N3 

= 1 contact  

         bistable 
 

with  
junction box 
A3

 = 1 contact  

         monostable 

B3

 = 1 contact  

         bistable 

0

 = without 

E

 = differential pres. 

      contr. with 
      constant outlet  
      pressure, valve  
       at input  
       ¼“ NPT, FPM 

= differential pres. 

       contr. with  
       constant inlet  
       pressure, valve  
       at output  
        ¼“ NPT, FPM 
 

= as ‚E‘ however  

      with FFKM  
      instead of FPM 

= as ‚A‘ however 

       with FFKM    
       instead  FPM 

= e.g. without  

       valve,  
       Please specify  

      in writing

4.0-40 

2.8 

KDG-9289...

1)

 

5.5-50 

2.8 

KDG-9270...

 

10-100 

2.8 

KDG-9271...

 

12-120 

2.8 

KDG-9290...

 1)

 

25-250 

2.8 

KDG-9272...

 

30-350 

2.8 

KDG-9273...

 

50-450 

2.8 

KDG-9274...

 

60-800 

2.8 

KDG-9275...

 

120-1200 

2.8 

KDG-9276...

 

 

200-2000 

2.8 

KDG-9277...

 2)

 

300-3000 

2.8 

KDG-9278...

 1)

 

Special 

range 

on re-

quest 

on re-

quest 

KDG-92YY... 

1) 

not available with contact 

2) 

only available for contacts with limited switching 

range 

3)

 at 1013 bar abs. and 20 °C 

4)

 not with differential pressure controller 

 

 

 
 
 
 
 
 
 

Summary of Contents for KDF-9

Page 1: ...Operating Instructions for Flow Meter Model KDF 9 KDG 9...

Page 2: ...DITIONS OF USE 7 6 1 Mounting start up 8 6 2 Ambient conditions 8 6 2 1 Ambient temperature ranges 8 6 2 2 Storage temperature 8 6 2 3 Climatic category 8 6 2 4 Degree of protection 8 6 2 5 Shock resi...

Page 3: ...ating personnel 12 15 PACKAGING STORAGE AND SHIPMENT 12 16 MAINTENANCE 12 ATTENTION 13 REPLACING THE MEASURING CONE 13 REMOVAL 13 INSTALLATION 13 17 RETURNING DEVICES FOR REPAIR AND SERVICE 15 18 DECO...

Page 4: ...avail able online may not always correspond to the product version you have purchased If you need an instruction manual that corresponds to the purchased product version you can request it from us fre...

Page 5: ...the measuring tube scale with the upper edge or the indicator edge of the float ball 2 1 KDF 9 KDG 9 system design The meter consists of a conical measuring tube made of glass containing a float that...

Page 6: ...values with fully opened valve Restricted contact adjustment range contact only adjustable as minimum contact Measuring ranges water 20 C Measuring ranges air 1 013 bar abs 20 C Float st 1 4401 316L...

Page 7: ...hin 10 100 of the range 5 3 Repeatability Liquid Gas 1 0 FS E F A B option differential pressure regulator 1 5 2 5 FS within 10 100 of the range 5 4 Influence of ambient temperature none 5 5 Influence...

Page 8: ...Void float impact e g caused by solenoid valves as this is likely to damage the measuring section or float 6 2 Ambient conditions 6 2 1 Ambient temperature ranges 20 C to 100 C with limit switch 20 7...

Page 9: ...re regulators are not pressure reduction valves The measuring device consists of variable area flowmeter with control valve and mounted differential pressure regulator The flow amount will be adjusted...

Page 10: ...2 Dimension drawing KDF 9 KDG 9 A B with conn NPT F as regulator c w constant inlet pressure 7 3 Weights KDF 9 KDG 9 0 4 kg KDF 9 KDG 9 E F A B 0 8 kg 7 4 Materials Fitting connections setting valve...

Page 11: ...respect to the Pressure Equipment Directive 2014 68 EU the devices fall within the scope of appli cation of Article 4 Section 3 and need no CE mark in accordance with this directive Kobold Messring c...

Page 12: ...ts 14 2 Installation start up and operating personnel Only trained specialists authorized by the system operator may carry out the installation electrical instal lations start up maintenance and opera...

Page 13: ...brush and appropriate media When assembling and reinstalling the system always new gaskets have to be used Replacing the measuring cone Removal Close valve in front and behind the unit Close needle va...

Page 14: ...ng the life cycle This requires tightening of the thrust piece 1 Loosen thread pin 2 M4x8 with hexagon 2mm and remove valve knob 3 Tighten thrust piece 1 SW14 with a torque of 3 8 Nm 4 0 Nm Caution Va...

Page 15: ...dous materials Consequently all devices sent to us for repair must be free of any hazardous materials This also applies to possible hollow spaces and fissures in the devices If repair is necessary con...

Page 16: ...asured medium Since this measured medium is dangerous in water poisonous corrosive flammable we have checked that all hollow spaces of the device are free of these materials neutralized and flushed al...

Page 17: ...1 Special range on re quest on re quest KDF 92YY Gases Order Details Example KDG 9288 NV 0 00 0 Measuring range air Nl h Valve seat mm Pressure drop mbar Order no stainless steel Connection Gasket op...

Page 18: ...gnetic compatibility EMC Part 6 3 Generic standards Emis sion standard for residential commercial and light industrial environments EN 55011 2011 Industrial scientific and medical equipment Radio freq...