Kobold KDF-9 Operating Instructions Manual Download Page 12

 

Operating Instructions KDF-9/KDG-9

 

 

KDF-9/KDG-9 K04/0922 

 

 

                                            Page 12 

11  Available accessories 

1 inductive limit switch ;  mono-stable or bi-stable 
Special connections 

12  Order information 

Please include the following information in your order: Product data,(specific weight, temperature, 
pressure, viscosity) material design, connection size, measuring range, desired accessories, required 
approvals and material certificates. 
 

13  Standards and directives 

Measuring range rated and converted to other products according to VDE/VDI guidelines 3513  
Directive 2014/68/EU (Pressure Equipment Directive) 

For the electrical sensor 

EN 60079-0 General regulations 
EN 60079-11 instrinsically safeness 
Guideline 2014/30/EU (EMC guidleine) 
NAMUR recommendation NE 21 
EN 60529 – Degrees of protection through housing (IP code) 
EN 61010-1 – Safety requirements for electrical measuring, control and laboratory devices 

14  Safety instructions 

14.1  Intended use 

The KDF-9/KDG-9 variable-area flow meter may be used only for flow measurements of fluid and gase-
ous media. The manufacturer shall not be liable for damage that may result from improper or unintended 
use. 
When dealing with an aggressive medium, clarify the material durability of all wetted parts. 

14.2  Installation, start-up and operating personnel 

Only trained specialists authorized by the system operator may carry out the installation, electrical instal-
lations, start-up, maintenance and operation.  They must read and understand the operating manual and 
follow its instructions. 
Basically, follow the conditions and provisions applicable in your country. 

15  Packaging, storage and shipment 

Carefully unpack the device to avoid damaging it.  With the help of the delivery note enclosed in the pack-
aging, check whether all technically relevant data coincide with your requirements.  
Storage and installation must be done in a clean and dry room so that contamination – especially of the 
interior of the fitting – is avoided.  Follow the limit values for ambient temperature. 
When transporting the device to a remote mounting location, we recommend that you reuse the factory-
issued packaging and the transport protection. 

16  Maintenance 

If you use the meter in the intended manner special maintenance is not necessary. However, the variable 
area flow meter should be checked in the context of the routine maintenance of the facility and the pipe-
lines. You have to eighth especially for dirt, corrosion denudation, mechanical wear as well damage at the 
glass cone. We recommend checking the meter once a year. 
In the recurrent pressure test of the system, the maximum allowed pressure test PT (see name plate) 
must not be exceeded.  

Summary of Contents for KDF-9

Page 1: ...Operating Instructions for Flow Meter Model KDF 9 KDG 9...

Page 2: ...DITIONS OF USE 7 6 1 Mounting start up 8 6 2 Ambient conditions 8 6 2 1 Ambient temperature ranges 8 6 2 2 Storage temperature 8 6 2 3 Climatic category 8 6 2 4 Degree of protection 8 6 2 5 Shock resi...

Page 3: ...ating personnel 12 15 PACKAGING STORAGE AND SHIPMENT 12 16 MAINTENANCE 12 ATTENTION 13 REPLACING THE MEASURING CONE 13 REMOVAL 13 INSTALLATION 13 17 RETURNING DEVICES FOR REPAIR AND SERVICE 15 18 DECO...

Page 4: ...avail able online may not always correspond to the product version you have purchased If you need an instruction manual that corresponds to the purchased product version you can request it from us fre...

Page 5: ...the measuring tube scale with the upper edge or the indicator edge of the float ball 2 1 KDF 9 KDG 9 system design The meter consists of a conical measuring tube made of glass containing a float that...

Page 6: ...values with fully opened valve Restricted contact adjustment range contact only adjustable as minimum contact Measuring ranges water 20 C Measuring ranges air 1 013 bar abs 20 C Float st 1 4401 316L...

Page 7: ...hin 10 100 of the range 5 3 Repeatability Liquid Gas 1 0 FS E F A B option differential pressure regulator 1 5 2 5 FS within 10 100 of the range 5 4 Influence of ambient temperature none 5 5 Influence...

Page 8: ...Void float impact e g caused by solenoid valves as this is likely to damage the measuring section or float 6 2 Ambient conditions 6 2 1 Ambient temperature ranges 20 C to 100 C with limit switch 20 7...

Page 9: ...re regulators are not pressure reduction valves The measuring device consists of variable area flowmeter with control valve and mounted differential pressure regulator The flow amount will be adjusted...

Page 10: ...2 Dimension drawing KDF 9 KDG 9 A B with conn NPT F as regulator c w constant inlet pressure 7 3 Weights KDF 9 KDG 9 0 4 kg KDF 9 KDG 9 E F A B 0 8 kg 7 4 Materials Fitting connections setting valve...

Page 11: ...respect to the Pressure Equipment Directive 2014 68 EU the devices fall within the scope of appli cation of Article 4 Section 3 and need no CE mark in accordance with this directive Kobold Messring c...

Page 12: ...ts 14 2 Installation start up and operating personnel Only trained specialists authorized by the system operator may carry out the installation electrical instal lations start up maintenance and opera...

Page 13: ...brush and appropriate media When assembling and reinstalling the system always new gaskets have to be used Replacing the measuring cone Removal Close valve in front and behind the unit Close needle va...

Page 14: ...ng the life cycle This requires tightening of the thrust piece 1 Loosen thread pin 2 M4x8 with hexagon 2mm and remove valve knob 3 Tighten thrust piece 1 SW14 with a torque of 3 8 Nm 4 0 Nm Caution Va...

Page 15: ...dous materials Consequently all devices sent to us for repair must be free of any hazardous materials This also applies to possible hollow spaces and fissures in the devices If repair is necessary con...

Page 16: ...asured medium Since this measured medium is dangerous in water poisonous corrosive flammable we have checked that all hollow spaces of the device are free of these materials neutralized and flushed al...

Page 17: ...1 Special range on re quest on re quest KDF 92YY Gases Order Details Example KDG 9288 NV 0 00 0 Measuring range air Nl h Valve seat mm Pressure drop mbar Order no stainless steel Connection Gasket op...

Page 18: ...gnetic compatibility EMC Part 6 3 Generic standards Emis sion standard for residential commercial and light industrial environments EN 55011 2011 Industrial scientific and medical equipment Radio freq...

Reviews: