background image

4

9

KOBE

P R O F E S S I O N A L

AIR TOOLS

TROUBLESHOOTING 

Continued

KOBE

P R O F E S S I O N A L

AIR TOOLS

BOX CONTENTS

KOBE

P R O F E S S I O N A L

AIR TOOLS

ELECTRICAL INFORMATION

In the United Kingdom, the

ELECTRICITY AT WORK ACT 1989 

requires all portable electrical appliances, if

used on business premises, to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at
least once a year. The 

HEALTH & SAFETY AT WORK ACT 1974

makes owners of electrical appliances

responsible for the safe condition of the appliance and the safety of its operator. If in any doubt about
electrical safety, contact a qualified electrician.

ELECTRICAL SAFETY

An RCCB (Residual Current Circuit Breaker) should be fitted in the mains electricity distribution board. If the
power supply is not protected by an RCCB, it is highly recommended that an RCD (Residual Current Device) is
used with all portable electrical products.  

PLUG FITTING

A moulded UK 3 pin plug with ASTA/BS approval is already fitted for your safety.
If it becomes damaged, and needs replacing, cut off the plug and prepare the
wires. Use the following instructions:

a)

Connect the GREEN/YELLOW earth wire to the earth terminal marked either 
‘ E’ or with the earth symbol‘   ’.

b)

Connect the BROWN live wire to the live terminal marked ‘ L’.

c)

Connect the BLUE neutral wire to the neutral terminal marked ‘ N’.

d)

After wiring, check there are no bare wires, that all wires have been correctly
connected, that the cable external insulation extends beyond the cable 
restraint and that the restraint is tight.

EXTENSION REELS

When a cable extension reel is used it should be fully unwound before being connected. Use at least 1.5mm

2

section cable or to be absolutely sure use 2.5mm

2

section cable.

Yellow & Green = Earth wire

Cable restraint

UK

ONLY

Brown = Live wire
Blue = Neutral wire

KOBE

P R O F E S S I O N A L

AIR TOOLS

SPECIFICATIONS

WORKING PRESSURE (max.)

..........

8Bar/115PSI

PUMP AIR DISPLACEMENT (min.)

.............................

....................................................................................

7.3CFM/210Ltr

AIR RECEIVER TANK CAPACITY

.......................

24Ltr

MOTOR CAPACITY

.......................................................

1.5KW

MOTOR ROTATION SPEED

...........................

2,850rpm

MOTOR SUPPLY VOLTAGE

.......................

230V/50Hz

MOTOR HP

..................................................................................

2HP

ACOUSTIC PRESSURE LWA (max.)

............

97dBa

NET DIMENSIONS

..................

61(H) x 55(W) x 34(D)cm

NET WEIGHT

...........................................................................

25.5kg

QUICK CONNECT COUPLER

.............1/

4

” BSP Female

The room temperature for its correct efficiency is 0

°

C

to +25

°

C (Max 45

°

C).

KOBE

P R O F E S S I O N A L

AIR TOOLS

SERVICE & REPAIR

A comprehensive repair and service
facility is available through your
local agent.

KOBE

P R O F E S S I O N A L

AIR TOOLS

SPARES

For spare parts or servicing please contact your nearest agent. Remember to quote tool model number and
spare part number when ordering spares. The use of other than genuine Kobe replacement parts may
result in safety hazards, decreased tool performance and increased maintenance. When disposing of
components, etc. ensure that relevant environmental procedures are carried out.

Air Intake Filter unit

KBE-298-3900A

Gasket ‘O’ ring

KBE-298-3910K

Drain valve

KBE-298-3911L

Valve set

KBE-298-3901B

x 2

x 2

x 1

x 1

x 4

x 2

x 1

x 1

x 2

x 1

Save the packaging
material for future
transportation of
the compressor in
the event of service
or repair.

Fig. 11

Valve seat

‘O’ ring

POSSIBLE CAUSE

The pre-set pressure
switch is defective or
needs adjusting.

Faulty safety blow off
valve.

SOLUTION

Stop the air compressor immediately and
contact your local Kobe agent.

Contact your local Kobe agent.

FAULT

The motor pump unit does
not stop when the tank
pressure reaches its
maximum working
pressure (116PSI) and the
safety valve vents air.

Safety blow off valve
operates below the
maximum pressure.

Reviews: