10

Max Tool

Bore x

Order Code

Weight

Length

Rating

KBE-280

1.5kg

6 x 700mm

150PSI

-1000K

Order Code

Description

KBE-280

1/4

BSP Mini Oiler

-1400K

MINI OILER

feeds oil directly into the airline ensuring

your air tool is well lubricated at all times preventing
corrosion. The clear body reservoir allows immediate 
inspection of the oil level. All brass construction.

RETRACTABLE AIR HOSE
BALANCER

with adjustable

tension return retracts
when the air tool is
released leaving the
workplace clear of
unwanted lengths of air
hose. Ideally suited for in
line production. 

WATER SEPARATOR

continuously removes

moisture from the air supply helping to prevent
corrosion to the internal components of the air
tool. The spring 
valve allows 
immediate 
draining of 
reservoir 
without 
any down time. 

HI-FLEX POLYURETHANE AIR HOSE 

with brass 360

°

swivel couplings, ideal for use in awkward access
areas. Recoils to a fraction of its working length leaving 
the workpiece clear of entanglement hazards.

WHIP HOSE AND ADAPTOR 

used

to supply air between the air tool
and supply point. Prevents
vibration damage to couplings and
the tool user.

EXHAUST HOSE ASSEMBLY 

deflects 

the tool exhaust away from the 
immediate work area and helps to 
reduce sound levels. Suitable 
for Kobe air tools. Thread size 

1/4

” NPT. Overall length 80cm.

HEAVY DUTY NYLON AIR HOSE

recoils to a

fraction of its working length when not in use
leaving the workplace clear of entanglement
hazards. Solid brass couplings with 360

°

swivel

and spring protectors allow use in any direction.

Order Code

Description

KBE-280

1/4

BSP Water Separator

-1900K

Overall

Order Code

Thread

Length

KBE-280

1/4

” NPT

650mm

-1360K

Inside Head

Suitable for

Order Code

Diameter

Kobe Air Tool models

KBE-298

GES2506L, GDA2206L, FDG090,

20mm 

FDG115, FDG180m & FDG180e.

-5421S

DP2210, DPR1810, DP513, DPR813, 

DAR1510, DS4510L, SH120,

25mm

SP1825K, GD2206L, GD22LK, 

-5420S

FPD500, FPD375 & X-GD16.

PU

Outside

Normal

Order Code

Connector

Diameter

Length

Rating

KBE-280

1/4

BSPT

6mm

7.5m

150PSI

-1160K

3/8

BSPT

10mm

7.5m

150PSI

-1320K

Nylon

Outside

Normal

Order Code

Connector

Diameter

Length

Rating

KBE-280

1/4

BSPT

6mm

7.5m

150PSI

-1140K

3/8

BSPT

10mm

7.5m

150PSI

-1300K

KOBE

P R O F E S S I O N A L

AIR TOOLS

SAFETY INSTRUCTION 

CONTINUED

3

Never use air tools on ladders. Ensure correct
platforms are used.

Never leave inflammable objects near the
compressor.

Never run the air compressor in areas exposed
to water or in damp conditions. 

Never direct  jets of water or flammable liquids
over the air compressor.

Never use the air compressor near naked
flames.

PERSONAL PROTECTION

Always wear approved eye protection during
operation. Use safety glasses or goggles which
conform to BSEN136 or CE equivalent that
provide protection from the front and side. The
operator of the air compressor and air tool is
responsible for following accepted eye, face,
respiratory, hearing and body protection.

Always wear approved footwear and headgear
when working on a building site or when heavy
weights and overhead working is involved.

Always ensure that all long hair and loose
clothing, ties, scarves, jewellery, etc., are
secured or removed. 

Always use approved hearing protection. High
sound levels can cause permanent hearing loss.

Always avoid inhaling dust or handling debris
from work processes which can be harmful to
your health

Always consult a doctor if numbness, tingling,
pain or whitening of the skin occurs. Repetitive
work motions, awkward positions and exposure
t o   v i b r a t i o n   c a n   c a u s e   “ R e p e t i t i v e   S t r a i n
Injuries”. 

Never operate the air compressor or air tools
near other people unless they are wearing
appropriate safety equipment also.

Never direct air at yourself, anyone else or at
animals.

SPECIFIC OPERATING HAZARDS

Always use recommended attachments or parts.

Always use the handle to move the compressor.
Do not move it by any other means.

Always place the air compressor on a firm and
level surface.

Always discharge the air from the air receiver
tank, when the compressor is not in use.

Always ensure the electric cable is not damaged
before connecting the air compressor to the
electricity supply.

A l w a y s   u s e   h o s e s ,   f i t t i n g s   a n d   c o u p l i n g s
designed for use with air compressors.

Always discharge the air receiver tank before the
air compressor is transported.

Always depress the pressure switch when the air
compressor is not in use. This will avoid any
unintentional starting.

Always close the tap and discharge residual
pressure in the air hose before disconnecting the
air hose from the compressor.

Always check for damaged or loose hoses and
fittings. Whipping hoses can cause serious
injury.

Always be careful when handling the compressor
as components such as the delivery pipe and the
cooling fins of the cylinder head can become very
hot and remain hot for some time after use. 

Never tamper with, or attempt to adjust the
pressure switch or the safety valve. The air
compressor must always be serviced by an
authorised agent.

Never use the air compressor without the air
filter attached.

Never deface the certification plate which is
attached to the end of the receiver tank.

Never pull the air compressor by the high
pressure hose or electric cable.

N e v e r   m a k e   a n y   a l t e r a t i o n s   t o   t h e   a i r
compressor and only use it for the task for which
it has been designed.

Never leave air tools connected to the air hose,
when not in use.

Never leave the air compressor connected to the
electric supply when unattended.

Never insert objects or your fingers inside the
safety grating of the cover to avoid physical injury
and also damage to the compressor.

Never operate the air compressor without all
guards or safety features in place and in proper
working order.

Never cover the air compressor or restrict air flow
around the machine whilst operating.

Never use the air compressor for filling breathing
tanks, diving tanks or for pharmaceutical, food or
health applications.