background image

Manufactured under license of 

Daewoo International Corporation, Korea

www.daewoopowerproducts.com

USER'S MANUAL

DAAC

24

D-OF / DAAC

50

D-OF

Air compressors

1. OPERATING INSTRUCTIONS

Please read and save these instructions. Rear carefully before attempting to assemble, install, 
operate or maintain the product described. Protect yourself and others by observing all safety   
informations. Failure go comply with instructions could result in personal and/or property damage!
Retain instructions for future reference.

DESCRIPTION 

Oilless air compressors are designed for do-it-yourselfers with a variety of home and automotive 
jobs. These compressors power spray guns, impact wrenches and other tools. These units operate 
without oil. Compressed air from this unit will contain moisture. Install a water filter or air dryer if 
application requires dry air.

SAFETY GUIDELINES

This manual contains information that is very important to know and understand. This information is 
provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, 
observe the following symbols.    

      DANGER!

 Danger indicates an imminently hazardous situation, which, if not avoided, will result 

in death or serious injury.

      WARNING!

 Warning indicates a potentially hazardous situation, which, if not avoided, could 

result to death or serious injury.

      CAUTION!

 Caution indicates a hazardous situation, which if not avoided, may result in minor or 

moderate injury.

      NOTICE! 

Notice indicates important information that if not followed, may cause damage to 

equipment.

UNPICKING

 After unpacking the unit, inspect carefully for any damage that may have occurred 

during transit. Make sure to tighten fittings, bolts, etc, before putting unit into service.

      WARNING!

 Do not operate unit if damage during shipment. Handling or use damage may result 

in bursting and cause injury or property damage.

      DANGER! 

Breathable Air Warning

This compressor is not equipped and should not be used “as is” to supply breathing quality air. For 
any application of air for human consumption, the air compressor will need to be fitted with suitable 
in-line safety and alarm equipment.

2. GENERAL SAFETY INFORMATION 

Since the air compressor and other components (material pump, spray guns, filters, lubricators, 
hoses,etc.) used, make up a high pressure pumping system, the following safety precautions must 
be observed at all times:
1. Read all manuals included with this product carefully. Be thoroughly familiar with the controls and 
the proper use of the equipment.

2. Follow all local electrical and safety codes.

3

Only persons well acquainted with these rules of safe operation should be allowed to use the 

compressor.

4. Keep visitors away and naver allow children in the work area.

5. Ware safety glasses and use hearing protection when operating the compressor or unit.

6. Do not stand on or use the compressor or unit as a handhold.

7. Before each use, inspect compressed air system and electrical components for signs of damage,
deterioration, weakness or leakage. Repair or replace defective items before using.

8. Check all fasteners at frequent intervals for proper tightness.

      WARNING! 

 Motors, electrical equipment and controls can cause electrical arcs that will ignite a 

flammable gas or vapor, Never operate or repair in or near a flammable gas or vapor, Never store 
flammable liquids or gases in the vicinity of the compressor.

      CAUTION! 

 Compressor parts may be hot even if the unit is stopped.

9. Keep fingers aways form a running compressor, fast moving and hot parts will cause injury and/or 
burns.

10. If the equipment should start to abnormally vibrate, STOP the engine/motor and check immedia-
tely for the cause, vibration is generally a warning of trouble.

11. To reduce fire hazard, keep enqine/motor exterior free of oil,solvent,or excessive grease.

      WARNING!

  Never remove or attempt to adjust safety valve. Keep safety valve free from paint 

and other accumulations.

      DANGER!

  Never attempt to repair or modify a tank! Welding, drilling or any other modification 

will weaken the tank resulting in damage from rupture or explosion . Always replace worn or dama-
ged tanks.

      WARNING!

  Drain liquid from tank daily.

13. Tanks rust from moisture build-up, which weakens the tank. Make sure to drain tank regularly 
and inspect periodically for unsafe conditions such as rust formation and corrosion.

14. Fast moving air will stir up dust and debris, which may be harmful. Release air slowly when 
draining moisture or depressurizing the compressor system.

SPRAYING PRECAUTIONS
      WARNING!

 Do not spray flammable material in vicinity of open flame or near ignition sources 

including the compressor unit.

15. Do not smoke when spraying paint, insecticides, or other flammable substances.

16. Use a face mask/respirator when spraying and spray in a well ventilated area to prevent health 
and fire hazards.

17. Do not direct paint or the other sprayed material at the compressor. Locate compressor as far 
away form the spraying area as possible to minimize overspray accumulation on the compressor.

18.  When spraying or cleaning with solvents or toxic chemical ,following the instruction provided by 
the chemical manufacturer.

3. ASSEMBLY 

WHEEL ASSEMBLY

Fit the wheels shown in Figure 1.

4. MAIN TECHNICAL DATE

 

Model: DAAC24D-OF

Voltage/Frequency: 220 - 240 V / 50 Hz
Power: 0.7 hp / 550 W
Capacity: 24 L
Cylinder: 2*63.7 mm  
Speed: 1440 rpm
Max pressure: 8 bar/115 psi
Flow: 106 L/min

5. INSTALLATION

LOCATION

It is extremely important to install the compressor in a clean , well ventilated area where the 
surrounding air temperature will not be more than 100

°F

.

A minimum clearance of 18inches between the compressor and a wall is required because objects 
could obstruct airflow.

      CAUTION!

  Do not locate the compressor air inlet near steam ,paint spray, sandblast areas or 

any other source of contamination. This debris will damage the motor.

ELECTRICAL INSTALLATION 
      WARNING!

  All wiring and electrical connections should be performed by a qualified electrician. 

Installation must be in accordance with local codes and national electrical codes.

      CAUTION!

  Never use an extension cord with this product. Use additional air hose instead of an 

extension cord to avoid power loss and permanent motor damage; Use of an extension cord voids 
the warranty.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal 230volt circuit and has a grounding plug that looks like the 
plug illustrated in Fig.2. Make sure the product is connected to an outlet having the same configura-
tion as the plug. This product must be grounded. In the event of an electrical shock by providing an 
escape wire for electric current. This product is equipped with a cord having a grounding wire with 
an appropriate grounding wire with an appropriate grounding plug. Plug must be plugged into an 
outlet that is properly installed and grounded in accordance with all local codes and ordinances.

      CAUTION!

  Improper use of grounding plug can result in a possible in a possible risk of electrical 

shock!

     

      DANGER!

  Do not use a grounding adapter with this product!

2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat 
blade terminal. The wire with insulation having an external surface that is green(with or without 
yellow stripes) is the grounding wire.

      WARNING!

  Never connect green (or green and yellow ) wire to a live terminal.

3. Check with a qualified electrician or serviceman if grounding instructions air not completely 
understood , or if in doubt as to whether product is properly grounded. Do not modify plug provi-
ded; If it will not fit outlet, have proper outlet installed by a qualified electrician.
4. Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be 
rated for at least the amperage and voltage indicated on motor nameplate, and meet all electrical 
codes for this minimum.
5. Use a slow blow fuse or a circuit breaker.

OPERATION

Pressure Switch: Auto/Off Switch-In the AUTO position , the compressor shuts off automatically 
when tank pressure reaches the maximum preset pressure. In the OFF position , the compressor 
will not operate. This switch should be in the OFF position when connecting or disconnecting the 
power cord from the electrical outlet or when changing air tools.

Regulator: The regulator controls the amount of air pressure released at the hose outlet.

Safety Valve: This valve automatically releases air if the tank pressure exceeds the preset maximum.

Discharge Tube: This tube carried compressed air from the pump to the check valve. This tube 
becomes very hot during use. To avoid the risk of severe burns, never touch the discharge tube.

Check Valve: A-one-way valve allows air to enter the tank ,but prevents air in the tank from flowing 
back into the compressor pump.

Handle: Designed to move the compressor.

      WARNING! 

 Never use the handle on wheeled units to lift the unit completely off the ground.

Drain Petcock- This valve us located on the bottom of the tank. Use this valve to drain moisture from 
the tank daily to deduce the risk of corrosion.
Reduce tank pressure below 10psi, and then drain moisture form tank daily to avoid tank corrosion. 
Drain moisture from tank by opening the drain petcock located underneath the tank.

LUBRICATION

This is an oilless product and does not require lubrication to operate.

BREAK-IN PROCEDUR
      CAUTION!

  Do not attach air chuck or other tool to open and of hose until start-up has been 

completed and unit checks ok.
IMPROTANT: Do not operate compressor before reading instructions or damage may result.
1. Turn regulate fully clockwise to open airflow.
2. Turn switch to OFF position and plug in power cord.
3. Turn switch to AUTO position and run unit for 30 minutes to break in the pump parts.
4. Turn regulator knob fully counterclockwise. Compressor will build to maximum preset pressure 
and shut off.
5. Turn regulator knob clockwise to cause air to bleed off. Compressor will result at a preset pressure.

6. Turn regulator knob counterclockwise to shut off the air and turn switch to off position.
7. Attach chuck or other tool to open end of hose, Turn the regulator on. In the AUTO position, the 
compressor pumps air into the tank. It shuts off automatically when unit reaches its maximum 
preset pressure. In the OFF position, the pressure switch cannot function and the compressor will 
not operate. Make sure switch is in OFF position when connecting or disconnecting power cord 
from electrical outlet.

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will from into droplets as it comes from an air compressor pump. 
When humidity is high or when a compressor is in continuous use for an extended period of time, this 
moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried 
from the tank through the hose, and out of the gun as droplets mixed with the spray material.

IMPORTANT:  

This condensation will cause water spots in a paint job, especially when spraying other 

than water based paints. If sandblasting , it will cause the sand to case and clog the gun rendering it 
ineffective . A filter in the air line ,located as near to the gun as possible ,will help eliminate this moistu-
re.

SAFETY VALVE
      WARNING! 

 Do not remove or attempt to adjust the safety valev!

This valve should be checked under pressure occasionally by pulling the ring by hand. If air leaks after 
ring has been released, or valve is stuck and cannot be actuated by ring, it MUST be replaced.

REGULATOR KNOB

 (figure 4)

1. This knob controls air pressure to an air-operated tool or paint spray gun.
2. Turn clockwise to increase air pressure at outlet. When desired pressure is reached, locked with 
nuts.
3. To lower air pressure at outlet,  turning counterclockwise. 

4. Turn fully counterclockwise to shut off flow of the air completely then push knob down.

TANK PRESSURE GAUGE

Gauge shows pressure in tank indicating compressor is building pressure properly.

6. MAINTENANCE       

            

      WARNING!

  Disconnect power source then release all pressure from the system before attempting 

to install, service, relocate or perform any maintenance.
Check compressor often for any visible problems and follow maintenance procedures each time 
compressor is used.

       

      WARNING!

 

Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released.

1. Pull ring on safety valve and allow it to snap back to normal position.

2. Turn compressor off and release pressure from system. Drain moisture from tank by opening drain 
cock underneath tank.
3. Clean dust and dirt from motor ,tank and airlines and pump cooling fins while compressor from 
clogging filter.

IMPORTANT: 

Locate unit as far from spraying area , as hose will allow preventing overspray from 

clogging filter.

LUBRICATION

This is an oilless type air compressor requiring no lubrication.

THERMAL OVERLOAD PROTECTOR
      CAUTION!

 

This compressor is equipped with an automatic reset thermal overload protector, which will  shut off 
motor if it becomes overheated.
If thermal overload protector shuts motor OFF frequently, look for the following causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.

7. TROUBLESHOOTING CHART

8. PARTS ILLUSTRATION 

9. PARTS ILLUSTRATION LIST

  No.   

Name   

 

QTY

  1 

Fan cover 

 

 

2

 

 

Bolt 

   4

  3 

Locking ring   

 

2

  4 

Lenft fan 

 

 

1

 

 

Bolt 

   4

 

 

Crank 

   2

  7 

Bearing 

 

 

2

 

 

Nut 

   4

  9 

Shock relief foot pad   

4

  10 

Left crankcase 

 

1

  11 

Bearing 

 

 

1

 

 

12 

Rotor 

   1

 

 

13 

Stator 

   1

  14  

Lock washer   

 

4

 

 

15 

Bolt 

   4

  16 

Bearing 

 

 

1

 

 

17 

Nut 

   4

  18 

Right crankcase 

 

1

  19 

Wire fasten ring 

 

1

  20 

Shrinkable tube 

 

2

  21 

Right fan 

 

 

1

 

 

22 

Bolt 

   2

  23 

Connect rod   

 

2

  24 

Piston ring 

 

 

2

  25 

Fasten plate   

 

2

 

 

26 

Bolt 

   2

  27 

Cylinder 

 

 

2

 

 

28 

O-ring 

   2

  29 

Valve plate 

 

 

2

  30 

Air pipe 

 

 

1

  31 

Air filter 

 

 

1

  32 

Cylinder cover  

 

2

  33 

Plain washers  

 

8

 

 

34 

Bolt 

   8

 

 

35 

O-ring 

   4

  36 

Connect pipe   

 

2

  37 

Exhaust head  

 

1

 

 

38 

Bolt 

   2

  39 

Fasten part   

 

2

  40 

Exhaust valve  

 

2

  41 

Cylinder cover seal ring 

2

  42 

Intake valve   

 

2

  43 

Metal cushion  

 

2

 

 

44 

Bolt 

   2

 

 

45 

Bolt 

   2

 

 

46 

Nut 

   2

Summary of Contents for DAAC24D-OF

Page 1: ...Manufactured under license of Daewoo International Corporation Korea www daewoopowerproducts com USER S MANUAL DAAC24D OF DAAC50D OF Air compressors ...

Page 2: ...ERATING INSTRUCTIONS 2 2 GENERAL SAFETY INFORMATION 3 3 ASSEMBLY 4 4 MAIN TECHNICAL DATE 5 5 INSTALLATION 5 6 MAINTENANCE 8 7 TROUBLESHOOTING CHART 9 8 PARTS ILLUSTRATION 11 9 PARTS ILLUSTRATION LIST 12 WARRANTY 13 ...

Page 3: ...ize this information observe the following symbols DANGER Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Warning indicates a potentially hazardous situation which if not avoided could result to death or serious injury CAUTION Caution indicates a hazardous situation which if not avoided may result in minor or moderate injury NO...

Page 4: ...system and electrical components for signs of damage deterioration weakness or leakage Repair or replace defective items before using 8 Check all fasteners at frequent intervals for proper tightness WARNING Motors electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair in or near a flammable gas or vapor Never store flammable li...

Page 5: ...g the compressor system SPRAYING PRECAUTIONS WARNING Do not spray flammable material in vicinity of open flame or near ignition sources including the compressor unit 15 Do not smoke when spraying paint insecticides or other flammable substances 16 Use a face mask respirator when spraying and spray in a well ventilated area to prevent health and fire hazards 17 Do not direct paint or the other spra...

Page 6: ...codes and national electrical codes CAUTION Never use an extension cord with this product Use additional air hose instead of an extension cord to avoid power loss and permanent motor damage Use of an extension cord voids the warranty GROUNDING INSTRUCTIONS 1 This product is for use on a nominal 230volt circuit and has a grounding plug that looks like the plug illustrated in Fig 2 Make sure the pro...

Page 7: ...AUTO position the compressor shuts off automatically when tank pressure reaches the maximum preset pressure In the OFF position the compressor will not operate This switch should be in the OFF position when connecting or disconnecting the power cord from the electrical outlet or when changing air tools Regulator The regulator controls the amount of air pressure released at the hose outlet Safety V...

Page 8: ...re In the OFF position the pressure switch cannot function and the compressor will not operate Make sure switch is in OFF position when connecting or disconnecting power cord from electrical outlet MOISTURE IN COMPRESSED AIR Moisture in compressed air will from into droplets as it comes from an air compressor pump When humidity is high or when a compressor is in continuous use for an extended peri...

Page 9: ...o install service relocate or perform any maintenance Check compressor often for any visible problems and follow maintenance procedures each time compressor is used WARNING Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released 1 Pull ring on safety valve and allow it to snap back to normal position 2 Turn compressor off and release pressure from system Drain...

Page 10: ... repeatedly CAUTION Never use an extension cord with this product 1 Incorrect size fuse circuit overloaded 2 Defective check valve or unloaded 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 2 Replace or repair DANGER Do not disassemble check valve with air in tank bleed tank Thermal overload protector ...

Page 11: ...e system 4 Broken inlet valves 5 Piston ring worn 1 Decrease usage or purchase unit with higher air delivery SCFM 2 Clean or replace 3 Replace leaking components or tighten as necessary 4 Replace compressor valves 5 Replace piston and cylinder Excessive moisture in discharge air 1 Excessive water in tank 2 High humidity 1 Drain tank 2 Move to area of less humidity use air line filter NOTE Water co...

Page 12: ...LUSTRATION 2 1 3 4 6 7 8 5 10 9 13 15 12 14 16 17 18 21 19 20 22 24 23 25 27 28 29 30 31 32 35 36 34 33 38 37 40 41 42 44 43 39 63 45 46 47 48 49 50 53 61 70 69 71 52 51 64 65 67 66 68 54 55 56 57 60 58 59 11 26 62 ...

Page 13: ...r filter 1 32 Cylinder cover 2 33 Plain washers 8 34 Bolt 8 35 O ring 4 36 Connect pipe 2 37 Exhaust head 1 38 Bolt 2 39 Fasten part 2 40 Exhaust valve 2 41 Cylinder cover seal ring 2 42 Intake valve 2 43 Metal cushion 2 44 Bolt 2 45 Bolt 2 46 Nut 2 No Name QTY 47 Capacitor protector 1 48 Capacitor 1 49 Terminal cap 2 50 Handle grip 1 51 Magnetic valve 1 52 Check valve 1 53 High pressure soft tube...

Page 14: ...www daewoopowerproducts com Manufactured under license of Daewoo International Corporation Korea ...

Reviews: