3 3 Serial Signal Measurement
3 4 Analyze AC signal by FFT
3 5 Waveform Save
4.1 General fault processing
-
-
-
To measure serial signals, as UART, IIC, SPI and etc, please take following steps:
1. Take 3.1 operations as reference, preliminary observe the measured signal.
2. Press “REC” while signal transmission.
3. Press “NEXT” or “Previous” according to prompt bar on the screen to check corresponding
page.
4. Take 3.2 (1) operations as reference, press “
”, “
” and “MODE” to move the cursor,
signal frequency can be measured.
Observe amplifying circuit in device, analyze output harmonic component and observe its
distortion by FFT.
To adopt FFT function, following steps can be taken.
1. Connect the input end of the amplifying circuit to sine wave signal.
2. Connect the oscilloscope probe to output end of amplifying circuit.
3. Take 3.1 operations as reference, proper signal can be observed.
4. Press ‘’F4 (FFT)”, observe frequency spectrum of output waveform for amplifying circuit
after Fast Fourier Transform.
5. Adjust the input signal source of amplifying circuit, observe FFT.
6. Press “F2 (
)” or “F3 (
)” to adjust position of red cursor, read corresponding
frequency and amplitude ratio of dominant wave and harmonic wave.
Waveform data save should be operated under static state, three ways lead to “static” state.
1. Press “HOLD” + “F2 (SAVE)”;
2. Press “REC” + “F2(SAVE)’’;
3. Press “FFT” + “HOLD” + “F1 (SAVE)”;
Then operate according to screen prompts.
1. If turn the oscilloscope switch to any gear, still black screen, no any display, please operates
by following steps:
(1) The Li-ion battery may be used out, please recharge it.
(2) Recharge the battery by matched charger for 5 to 10 minutes, try again.
(3) If still no display, Li-ion battery may be damaged, need to change.
2. Press “AUTO”, if waveform of signal doesn’t display on the screen, please take following
steps:
(1) Verify if the probe is correctly connected to signal cable.
(2) Verify if the signal cable is correctly connected to connector.
(3) Verify if the probe is correctly connected to measured object.
(4) Verify if the measured object emits signals.
Fault Processing
4.
52
Oscilloscope Section
Summary of Contents for Meterbox KMOS-01
Page 2: ... ...
Page 4: ... ...
Page 5: ...www grupotemper com KMOS 01 Multímetro ...
Page 36: ...TrueRMSMultímetro ...
Page 37: ...www grupotemper com KMOS 01 Sección osciloscopio ...
Page 56: ...OscilloscopeSection ...
Page 57: ...www grupotemper com KMOS 01 Meterbox Guía de usuario ...
Page 68: ...Rev 111213 ...
Page 70: ... ...
Page 72: ...Verdadeiro RMS Multímetro 6 ...
Page 73: ...www grupotemper com KMOS 01 Verdadeiro RMS Multímetro ...
Page 104: ...Verdadeiro RMS Multímetro ...
Page 105: ...www grupotemper com KMOS 01 Seção do osciloscópiop ...
Page 124: ...Seção do Osciloscópio ...
Page 125: ...www grupotemper com KMOS 01 Guia do usuário do Meterbox ...
Page 136: ...Rev 111213 ...
Page 138: ...Verdadeiro RMS Multímetro 2 ...
Page 140: ...Verdadeiro RMS Multímetro 4 ...
Page 141: ...www grupotemper com KMOS 01 Multimètre et oscillomètre RMS rèel ...
Page 174: ...www grupotemper com KMOS 01 Section oscilloscope ...
Page 192: ...56 Multimère et oscillomètre RMS réel ...
Page 193: ...www grupotemper com KMOS 01 Guide de l utilisateur de Meterbox ...
Page 205: ......
Page 207: ......
Page 208: ...www grupotemper com KMOS 01 True RMS Multimeter ...
Page 239: ...True RMS Multimeter ...
Page 240: ...www grupotemper com KMOS 01 Oscilloscope Section ...
Page 259: ...Oscilloscope Section ...
Page 260: ...www grupotemper com KMOS 01 Meterbox User s Guide ...
Page 271: ...Rev 111213 ...