CAP
Hz
%
Temp
10A
mA
μA
Ω
mV
V
OSC
Hz
%
4-4.Page Area
4-5.Softkey Labels
The page area of the display is where the main meter content is displayed.
The primary display (upper half of the page area) is where the most important value of the
selected function is shown. The secondary display contains the bar graph and values that may
be measured in addition to the primary function value. For example, with frequency measurement
selected in Vac, the frequency value will appear in the primary display with the ac voltage value
in the secondary display.
Labels for the four function softkeys (F1 through F4) appear in the bottom row of the display.
These labels will change based on the function and/or menu selection.
DC(AC) and AC+DC voltage measurements
AC voltage measurements
DC(AC) millivolts, ac+dc millivolt measurements
Frequency measurements
Resistance, Diode test, Capacitance and Continuity measurements
Temperature measurements
AC, DC and AC+DC amps measurements
AC, DC and AC+DC milliamps measurements
AC, DC and AC+DC microampere measurements up to 5,000 A
μ
4-6.Understanding the Rotary Switch
4-7.Using the Input Terminals
Select a primary measurement function
by positioning the rotary switch to one of
the icons around its perimeter. For each
function, the Meter presents a standard
display for that function (range, measurement units, and modifiers). Button
choices made in one function do not carry over into another function.
All functions except current use the VOHMSand COM input
terminals. The two current input terminals (A and mA/ A) are
Used as follows:
Current from 0 to 500 mA, use the uAmA and COM terminals.
Current between 0 and 10 A use the A and COM terminals.
μ
Input for 0 A to 10.00 A current (20VA overload for 30 seconds
on, 10 minutes off),
Input for 0 A to 500 mA current measurements.
Return terminal for all measurements.
Input for voltage, continuity, resistance, diode test, conductance,
capacitance.
V
CAP
Ω
Hz
%
Temp
CAT III 600V
10
True RMS Multimeter
Summary of Contents for Meterbox KMOS-01
Page 2: ... ...
Page 4: ... ...
Page 5: ...www grupotemper com KMOS 01 Multímetro ...
Page 36: ...TrueRMSMultímetro ...
Page 37: ...www grupotemper com KMOS 01 Sección osciloscopio ...
Page 56: ...OscilloscopeSection ...
Page 57: ...www grupotemper com KMOS 01 Meterbox Guía de usuario ...
Page 68: ...Rev 111213 ...
Page 70: ... ...
Page 72: ...Verdadeiro RMS Multímetro 6 ...
Page 73: ...www grupotemper com KMOS 01 Verdadeiro RMS Multímetro ...
Page 104: ...Verdadeiro RMS Multímetro ...
Page 105: ...www grupotemper com KMOS 01 Seção do osciloscópiop ...
Page 124: ...Seção do Osciloscópio ...
Page 125: ...www grupotemper com KMOS 01 Guia do usuário do Meterbox ...
Page 136: ...Rev 111213 ...
Page 138: ...Verdadeiro RMS Multímetro 2 ...
Page 140: ...Verdadeiro RMS Multímetro 4 ...
Page 141: ...www grupotemper com KMOS 01 Multimètre et oscillomètre RMS rèel ...
Page 174: ...www grupotemper com KMOS 01 Section oscilloscope ...
Page 192: ...56 Multimère et oscillomètre RMS réel ...
Page 193: ...www grupotemper com KMOS 01 Guide de l utilisateur de Meterbox ...
Page 205: ......
Page 207: ......
Page 208: ...www grupotemper com KMOS 01 True RMS Multimeter ...
Page 239: ...True RMS Multimeter ...
Page 240: ...www grupotemper com KMOS 01 Oscilloscope Section ...
Page 259: ...Oscilloscope Section ...
Page 260: ...www grupotemper com KMOS 01 Meterbox User s Guide ...
Page 271: ...Rev 111213 ...