2-12 Display System
•After startup, actual time and date display at the top
left corner on the interface, format: mm/dd/yy,
hh/mm/ss (picture 2-10-1).
•Function of the clock is supplied by the back-up
battery inside of the device, which can work for 5 to
10 years, and irrelevant to the Li-ion rechargeable
battery.
•Take “Operating Instructions For Oscilloscope” for
reference for the adjustment of clock.
•After startup, at the top right corner, display the working
Li-ion rechargeable battery electric power (picture 2-10-2).
•The battery fully charged, 4 cells.
•When 1 cell left, blue color turn to red, warning to
recharge, 30 to 45 minutes may be used by this left
power.
•All cells disappear, please recharge promptly, 15 to
20 minutes may be used by this left power.
The oscilloscope displays forms of voltage relative to time, and helps user measure and display
waveforms. Two ways of measurements can be adopted: Scale measurement or cursor
measurement.
Fast and direct evaluation can be done by this way, for example, waveform amplitude can be
observed to judge whether it’s 0.8V or not.
By calculating relevant primary and secondary scale division, then multiplying by proportion
factor, simple measurement can be taken.
For example, if four main vertical scale divisions between the waveform peak and base are
figured out, proportion factor is 200 mV/division, peak value voltage can be calculated by the
following method: 4 divisions * 200mV/div= 0.8V
As the following picture shows, press “HOLD” or “REC”, “V/Fcursor” appear in prompt bar,
indicates function switch button for cursor measurement.
1. Blue vertical cursor appears on the displayed screen, press “
” to move the cursor, one
time for one space, press this key for more than 1 second for fast move, the cursor moves
continuously in the same direction.
2. Press “MODE” to switch left/right cursor, lighter cursor indicates state of activation.
3. Display mode of frequency and cycle is also switched at the time of left/right cursor switch.
Activate left cursor displays frequency, right cursor for cycle. See picture 2-11-1.
2 12 1 Time and Date
2 12 2 Battery Electric Power Display
2 13 Measuring System
2 13 1 Scale Measurement
2 13 2 Movement of Cursor
-
-
-
-
-
-
-
-
-
Picture 2-10-1
Picture 2-10-2
48
Oscilloscope Section
Summary of Contents for Meterbox KMOS-01
Page 2: ... ...
Page 4: ... ...
Page 5: ...www grupotemper com KMOS 01 Multímetro ...
Page 36: ...TrueRMSMultímetro ...
Page 37: ...www grupotemper com KMOS 01 Sección osciloscopio ...
Page 56: ...OscilloscopeSection ...
Page 57: ...www grupotemper com KMOS 01 Meterbox Guía de usuario ...
Page 68: ...Rev 111213 ...
Page 70: ... ...
Page 72: ...Verdadeiro RMS Multímetro 6 ...
Page 73: ...www grupotemper com KMOS 01 Verdadeiro RMS Multímetro ...
Page 104: ...Verdadeiro RMS Multímetro ...
Page 105: ...www grupotemper com KMOS 01 Seção do osciloscópiop ...
Page 124: ...Seção do Osciloscópio ...
Page 125: ...www grupotemper com KMOS 01 Guia do usuário do Meterbox ...
Page 136: ...Rev 111213 ...
Page 138: ...Verdadeiro RMS Multímetro 2 ...
Page 140: ...Verdadeiro RMS Multímetro 4 ...
Page 141: ...www grupotemper com KMOS 01 Multimètre et oscillomètre RMS rèel ...
Page 174: ...www grupotemper com KMOS 01 Section oscilloscope ...
Page 192: ...56 Multimère et oscillomètre RMS réel ...
Page 193: ...www grupotemper com KMOS 01 Guide de l utilisateur de Meterbox ...
Page 205: ......
Page 207: ......
Page 208: ...www grupotemper com KMOS 01 True RMS Multimeter ...
Page 239: ...True RMS Multimeter ...
Page 240: ...www grupotemper com KMOS 01 Oscilloscope Section ...
Page 259: ...Oscilloscope Section ...
Page 260: ...www grupotemper com KMOS 01 Meterbox User s Guide ...
Page 271: ...Rev 111213 ...