KPAW-01
TRUE RMS 1000A AC WATT Clamp Meter
lead (COM input terminal) to the corresponding three
phases loaded neutral wire.
4. Press
SEL
to select phase location, the display shows the
corresponding phase symbol.
L1
means the first phase
,
L2
means the second phase
,
L3
means the third phase
.
5. The display shows the corresponding True RMS voltage
value and frequency value of each phase.
6. Press
MAXMIN
, the LCD displays
, it starts
recording the maximum AC voltage True RMS value.
7. Press
MAXMIN
the LCD displays
, it starts recording
the minimum AC voltage True RMS value. Press
MAXMIN
again to show the current AC voltage True RMS value.
8. The display shows
0L
when the input voltage is higher
than 750V rms.
Note
When the measurement has been completed,
disconnect the connection between the testing leads and
the circuit under test and remove testing leads from the
input terminals.