KDH-BAT
Smoke Alarm
www.grupotemper.com
KDH-BAT Smoke Alarm User’s Manual
KDH-BAT are photoelectric smoke alarm, it is generally more effective at detecting smoldering
fires which smolder for hours before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding. KDH-BAT accords with the ISO/DIS 12239 Standard.
IMPORTANT! PLEASE READ CAREFULLY AND KEEP IT.
This user’s manual contains important information about
your smoke alarm’s operation. To insure your safety, you need install one alarm at least in your every single room. Please
don’t open the smoke alarm for that may cause improper effect. If you are installing this smoke alarm for use by others, you
must leave this manual –or a copy of it—with the end user.
TECHNICAL PARAMETER
DC power: Battery 9V
Static Current: <10uA
Alarm Current:<12mA
Low Voltage Alarm: 6.5V~7.2V
Current:<25 mA
Alarm sonority:> 85 db (3m)
Working temperature:-10
℃
~40
℃
WHERE TO INSTALL SMOKE ALARMS
1.
At first, you need install them in your bedroom and routeway, and should install one item in every bedroom at least.
2.
Stairway is important for you to rush out when fires occur, so there must install smoke detectors.
3.
You at least require one smoke alarm on every floor, including finished attics and basements.
4.
Install one alarm beside every electric facility.
5.
Install smoke alarms in the middle of ceiling, because smog, heat and flashes always lift to the top of rooms
6.
If some reasons cause you can’t install them in the middle of ceiling, you need to install them at least 10cm away from
the wall.
7.
If you like to install them on the wall, they should be installed 10-30.5cm away under the ceiling. Diagram 1.
BEST HERE
CEILING
1
0
C
M
(4
'')
3
0
.5
C
M
(1
2
'')
SIDE WALL
M
A
X
IM
U
M
ACCEPTABLE HERE
NEVER HERE
M
IN
IM
U
M
MINIMUM
10CM(4'')
DIAGRAM 1