background image

 

 

 

                                           

LCD Hourly Programmable Thermostat 

                                    Code: 0769008, Reference: KT8-LCD-P 

 

A. 

Installation, Mounting 

 

Caution:  Turn off 0769008 and the electrical devices (e.g. heater, cooler) which will be 

connected before installation. 

It is highly recommended that the installation procedure is processed by trained 
personnel. 

 

1.

 Installation Location 

The  thermostat  should  be  mounted  on  an  inner  wall  1.5m  above  the  floor  in  position 
where  it  is  readily  affected  by  changes  of  the  general  room  temperature  with  freely 
circulating  air.  Prevent  direct  exposure  to  sunlight;  dripping  or  splashing  area.  Do  not 
place this unit at a location where air circulation is low, or where it has great temperature 
changes (e.g. near door). Do not place the thermostat near heat/cool generating sources. 

 

2.

 

Wiring 

There  are  3  wiring  terminals  at  the  bottom  of  0769008  base  housing,  labeled  as 
"C"(COOL),  "H"(HEAT)  and  "L”(LIVE).  Connect  Cooler  and  Heater  to  the  "COOL” 
and "HEAT" terminals. Leave unused holes blank. 
Wire the correct cables to the terminal block according to the circuit diagram at the back 
of the thermostat. Push all cables back into wall prior to fixing to avoid trapping wires. It 
is recommended that a 6A fuse is fitted.   

 

3.

 

Mounting 

5.

 

Remove front part by placing the screw driver between front part and wallplate and 
pull front part up and away (Step 1) 

6.

 

Rotate  the  plastic  screw  at  the  cover  door  to  horizontal  position  to  open  the  cover 
door (Step 2 and 3) 

7.

 

Follow the diagram at the back of wallplate to wire the cables. (Step 4) 

8.

 

Close and lock the cover door by turning the plastic screw to vertical position. (Step 
5 and 6). 

9.

 

Use the provided screws and wall anchors to mount the wallplate with the key-hole 
at the back. (Step 7) 

10.

 

Place the new batteries according to the marking on the battery drawer. (Step 8) 

11.

 

Engage tabs at the top of 0769008 and wallplate (Step 9) 

12.

 

Press lower edge of case and latch (Step 10) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Remarks: 

Before latching the front part with the wallplate, make sure the three connect 

pins insert into the terminal block contact holes precisely.       

 
 

                           

 

 

 

 

 

 

 

 

 

 

 

 

 
B.  Start/Reset 

1.

 

After wiring and  mounting, switch off all the connected devices. Place 2 new AA 1.5V 
alkaline batteries according to the polarities marked. LCD display will be switched on. 

2.

 

Press ‘RST’ to reset. 0769008 will be ready to control the heater / cooler.     

3.

 

Switch  On  the  heater  /  cooler.  The  heater  /  cooler  will  remain  OFF  until  0769008 
activates the output ON with 

  rotating. 

 

C. Operation 

1.

 

Slide Switch 

i.

 

Heat/ Off/ Cool Slide Switch 

Set the HEAT/OFF/COOL slide switch at HEAT 

<

   

>

 position in winter and at 

COOL 

<

 

 

>

  position  in  summer.  Set  the  slide  switch  at  OFF       

<

 

 

position to turn off the thermostat. 

ii.

 

Delay/ No Delay Slide Switch 

The slide switch inside the unit sets the minimum off time of the heater/cooler: 
 

 

        HEAT 

 

COOL 

NO DELAY          10 secs 

 

5 mins 

DELAY                    5 mins 

              5 mins 

      Note: When COOL is set, the minimum off time is fixed at 5 minutes. 

 

D.  Normal Time Setting Mode 

1.

 

Press 

<

>,

  the  Day  of  Week  (1-7)  will  flash,  press 

<

/

  <

>

  to  set  the  Day  of 

Week. 

2.

 

Press 

<

>,

 the Hour will flash, press 

<

/

 <

>

 to set the Hour. 

3.

 

Press 

<

>

, the Minute will flash, press 

<

/

 <

>

 to set the Minute. 

4.

 

Press 

<

>

 will jump back to the step 1. 

5.

 

Press  <

>  to  confirm  the  settings  and  return  to  Normal  Mode.    Or  operation  will 

return to normal mode after 10 seconds. 

6.

 

Jumper selection for 12/24HR display can be selected on the PCB inside the unit during 
installation. Factory pre-set setting is 24HR. 

 

E.  Setting Program 

1.

 

Press <PRG>, the Day of Week (1-7) will flash, press 

<

/

 <

to select the Day for 

program adjustment. 

2.

 

Press <PRG>, the Program Number P(0~6,8,10~16,18) will flash.   

3.

 

Press 

<

/

 <

>

 to select the desired Program number. 

 

i.

 

Factory Defined Programs - FTY PROG (0-6,8):

 

 

_ : Economy temperature setting         

 

: Comfort temperature setting

 

 

 

ii.

 

User Program - USER PROG (10~16,18): 

I.

 

Press 

<

/

 <

to select the user program. 

II.

 

Press <

<

  >

 to select comfort / Economy setting for each hour. 

4.

 

Press 

<

jump back to Normal Time Mode, or auto-return after 10 seconds. 

 

F.  Comfort and Economy Temperature Setting 

1.

 

Hold  <

<

  >

  for  1  sec  will  enter  Comfort  and  Economy  Temperature  Setting 

mode. 

2.

 

Press 

<

/

 <

>

 to adjust the temperature setting. 

3.

 

Press 

<

>

 jump back to Normal Time Mode, or auto-return after 10 seconds. 

G.  Temporary Override Mode 

1.

 

Temporary  Override  Mode  can  change  the  current  program  mode  to  the  opposite 
program mode temporarily.    The time when next program of opposite state or the 
next day is reached, Temporary Override mode will be released automatically. 

2.

 

When  the  current  program  mode  is  Comfort

,  press 

<

>

  will  enter  the 

Temporary  Override  mode  and  with 

  displayed.    On  the  other  hand,  when 

the  current  program  mode  is  Economy

,  press  <

>  will  enter  Temporary 

Override mode and with 

  displayed. 

3.

 

Follow section F to set the setting temperature if necessary. 

4.

 

Press <

/

 

< >

 of opposite state can release Temporary Override mode. 

 

H. Comfort / Economy Hold Timer 

1.

 

Comfort  /  Economy  Hold  Timer  can  force  the  thermostat  to  run  at  either  Comfort 
mode or Economy mode for a defined period of time. 

2.

 

Hold  <

>  for  1  sec  &  press  <

>  will  enter  the  Comfort  Hold  Timer  with 

 

and  Hour  digit  flashing.    On  the  other  hand,  hold  < >  for  1  sec  and  press  < > 

will enter the Comfort Hold Timer with 

  and Hour digit flashing. 

3.

 

Press 

<

/

 <

>

 to adjust the number of hours for hold timer. 

4.

 

Press 

<

>

 to confirm setting and back to Normal Time Mode, or auto-return after 

10 sec. 

5.

 

Follow section F to set the setting temperature if necessary. 

6.

 

Press <

/

 

< >

 of opposite state can release the Hold Timer. 

 
I.  Special Conditions

 

1.

 

If  battery  is  LOW,  “C”, “P”  and  “  :  “will  be  flashing,  the  recent  batteries  must  be 
replaced with new one. 

2.

 

When  room  temperature  is  below  5°C,  Defrost  “df”  is  displayed.  Heat  output  will 
turn ON and Cool output will turn OFF.   

3.

 

Below 0°C, 

L

 is displayed. Heat output will turn ON and Cool output will turn OFF. 

4.

 

Above  39.5°C, 

H

  is  displayed.    Heat  output  will  turn  OFF  and  Cool  output  will 

turn ON. 

 

J.    Replace The Battery 

Caution:  Turn  off  the  electrical  devices  and  disconnect  the  supply  to  the 
appliances  before  replacing  the  batteries.  Replace  only  with  the  same  or 
equivalent  type  of  batteries.  Do  not  dispose  the  used  batteries  with  household 
waste. Refer to your local area for the proper disposal. 

 

1.

 

Remove front part by placing the screw driver between front part and all 
plate and pull front part up and away (Step 1 of figure 1). 

2.

 

Pull out the batteries.   

3.

 

Place  the  new  batteries  according  to  the  marking  on  the  battery  drawer 
(Step 8 of figure 1). 

4.

 

Dispose the old batteries properly. 

5.

 

Engage tabs at the top of 0769008 and wallplate (Step 9 of figure 1). 

6.

 

Press lower edge of case and latch (Step 10 of figure 1). 

7.

 

Check if the thermostat works properly or not. 

8.

 

Press “RST” if necessary. 

 

K.  Specification 

    1.  Temperature measurement:  0.0 - 39.5°C (0.5°C/step) 
    2.  Accuracy:   

 

± 0.5°C 

    3.  Temperature control range:  5.0 - 35.0°C (0.5°C/step) 
    4.  Switching:   

 

24..250VAC 50/60Hz 6A resistive max 

    5.    Terminals:   

 

2.5mm

2

 cable   

6.    Electronic control:   

Type 2.B action 

7.  Battery: 

 

 

2 x 1.5V AA alkaline batteries 

    8.  Operating temperature: 

0 - 50°C 

    9.  Storage temperature:  

0 - 60°C 

 

TEMPER ENERGY INTERNATIONAL S.L. 

Polígono industrial de Granda, nave 18 

33199 • Granda - Siero • Asturias 

Teléfono: (+34) 902 201 292 

Fax: (+34) 902 201 303 

Email: [email protected]                                                                                     

www.grupotemper.com

                                                                                         

140904 

Figure 1 

Terminal block   
contact holes 

Summary of Contents for 0769008

Page 1: ...ado o comienza el siguiente día el modo de anulación temporal se cancela automáticamente 2 Si la unidad se encuentra en el modo confort de anulación temporal y se mostrará el icono económico mostrará el icono 3 Consulte 4 Pulse la tecla cancelar el modo de anulación temporal H Temporizador de suspensión del modo confort económico 1 El temporizador de suspensión se utiliza para hacer que el termost...

Page 2: ...justment 2 Press PRG the Program Number P 0 6 8 10 16 18 will flash 3 Press to select the desired Program number i Factory Defined Programs FTY PROG 0 6 8 _ Economy temperature setting Comfort temperature setting ii User Program USER PROG 10 16 18 I Press to select the user program II Press to select comfort Economy setting for each hour 4 Press jump back to Normal Time Mode or auto return after 1...

Page 3: ...ntrer au mode de réglage de température 2 Appuyez sur pour ajuster la température 3 Appuyez sur G Mode manuel temporaire 1 Le mode manuel temporaire peut changer le mode de programme actuel et l inverser temporairement Au prochain changement de mode réglé ou le jour suivant le mode manuel temporaire sera automatiqu 2 Quand le programme actuel est confort mode manuel temporaire et actuel est éco 3 ...

Page 4: ...a PRG o Número de Programa P 0 6 8 10 16 18 irá piscar 3 Prima para selecionar o número do Programa desejado i Programas Definidos de Fábrica FTY PROG 0 6 8 _ Definição de temperatura económica Definição de temperatura conforto ii Programa de Utilizador USER PROG 10 16 18 I Prima para selecionar o programa do utilizador II Prima para selecionar a definição Conforto Economia para cada hora 4 Prima ...

Reviews: