KNX Jung 230011SU Operating Instructions Manual Download Page 3

Switch actuator, 1-gang

Updateable with Jung ETS Service App

Characteristics switch operation

Operation as NO or NC contacts

Feedback function

Logic and restraint function

Central switching functions

Time functions: switch-on delay, switch-off delay, staircase lighting timer with run-on time

Scene function

Operating hours counter

Characteristics extension inputs

Switching operating function

Dimming operating function (incl. colour temperature dimming)

Shutter/Venetian blinds operating function

Value transmitter operating function (1-byte, 2-byte, 3-byte and 6-byte incl. RGBW and
colour temperature presets)

Scene extension operating function

2-channel operation operating function

Controller extension operating function

Disabling functions

Debounce time adjustable

Logic function characteristics

Logic gates

Transformer (conversion)

Disabling element

Comparator

Limit value switch

4

Information for electrically skilled persons

 DANGER!

Mortal danger of electric shock.

Disconnect the device. Cover up live parts.

4.1 Fitting and electrical connection

 DANGER!

When connecting the bus/extensions and mains voltage wires in a shared appliance
box, the KNX bus line may come into contact with the mains voltage.

This endangers the safety of the entire KNX installation. People at remote devices
may also receive an electric shock.

Do not place bus/extensions and mains voltage terminals in a shared connection
compartment. Use an appliance box with a fixed partition wall or separate appliance
boxes.

Connecting and fitting the device

In secure operation (preconditions):

Secure commissioning is activated in the ETS.

3 / 8

82404313

25.05.2021

J0082404313

Summary of Contents for Jung 230011SU

Page 1: ...tallation that there is always sufficient insula tion between the mains voltage and the bus A minimum distance of at least 4 mm must be maintained between bus conductors and mains voltage cores Danger...

Page 2: ...ula tion in building automation and can be configured in the ETS project Detailed specialist know ledge is required A device certificate which is attached to the device is required for safe com missio...

Page 3: ...n Disabling functions Debounce time adjustable Logic function characteristics Logic gates Transformer conversion Disabling element Comparator Limit value switch 4 Information for electrically skilled...

Page 4: ...ronic device box with partition Ob serve cable routing and spacing Figure 3 Figure 3 Mounting example in electronic device box with partition wall series push button and NTC temperature sensor 5 Appli...

Page 5: ...er with COM connections of other devices 4 2 Commissioning Commissioning the device NOTICE Undefined relay state at delivery Unexpected control of connected loads During commissioning before switching...

Page 6: ...ice setting physical address 15 15 255 firmware re mains in place The device must then be recommissioned with the ETS During secure operation A master reset deactivates device security The device can...

Page 7: ...of switching current per 5 C in excess of 35 C 10 when installed in wooden or dry construction walls 15 when installed in multiple combinations 20 Clampable conductor cross section single stranded 0...

Page 8: ...itch actuator 1 gang ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de 8 8 82404313 25 05 2021 J008240431...

Reviews: