background image

INTERCONNECTION DIAGRAM

7

  1 

Welder 

1 set

  2 

Operator’s Manual 

1 pc

  3 

Electrode Holder 

1 pc

No.

Description

Qty.

TRANSPORTATION AND STORAGE

NOTES: All above mentioned are based on the ordering contact unless otherwise agreed by the parties.

   • This machine is an indoor equipment and the attacks of

      rain and snow should be avoided in the process of

      transportation and storage. While loading and unloading,

      more attention should be paid on the package with words

      of warning. Storage warehouse should be kept dry with

      good air circulation and no corrosive gas or dust. 

      The temperature should be maintained from -25º C to 55º C

      and relative humidity must be lower than 90%.

   • If the products are still needed to continue storing after 

      stripping, repacking should be carried out according to

      original package’s requirement. Remember before storage,

      don’t forget to clean and seal it with plastic bags.
   • Users should maintain the cartons and shock blocks in order

       to be properly packaged in need of long distant transportation.   

       For the long distant transportation, it should be retrofitted 

       with a wooden case and mark the “up” or “rain” symbols.

  4 

Earth Clamp 

1 pc

  5 

Face Mask with Filter 

1 pc

  6 

Brush & Hammer 

1 pc

No.

Description

Qty.

ACCESSORIES

min

32
50
62
96

max

40
60
75

128

1.6 mm
2.0 mm
2.5 mm
3.2 mm

1/16”
5/64”
3/32”

1/8”

ROD DIAMETER

Amperage ratio according to electrode diameter

(Approximate value)

Note:

 The table is only informative, it does not mean that the

           equipment can operate all the listed electrodes and diameters,

           only those that the amperage and duty cycles allow.

JOB SUGGESTION

min

120
200
256

max

160
250
320

4.0 mm
5.0 mm
6.4 mm

5/32”
3/16”

1/4”

ROD DIAMETER

ECN Soldering Iron

Circuit Schematic

(Reference figures

are subject to change

without notice).

Summary of Contents for KN INW-160

Page 1: ...KN INW 160 KN INW 200 Inverter welding machine160A Soldadora tipo inversora STICK TIG LIFT Inverter welding machine200A Soldadora tipo inversora STICK TIG LIFT...

Page 2: ...g positive and negative output terminals without insulated protection ITEM MODEL Input power Compatible with CD CA electrodes Rated input capacity Rated input current KN INW 160 110 220V 50 60 Hz Yes...

Page 3: ...ionals to change or replace the welder Since the welder owns strong electromagnetic and radio frequencies the people with cardiac pacemakers affected by the interference electromagnetic electrical fre...

Page 4: ...it is strictly prohibited that ground wire is connected to the grid otherwise bear your own consequences Electrode Polarity see above picture Connect the quick plug with electrode holder to the posit...

Page 5: ...maximum is 160 Second time Hot Start The display code is Hot Clockwise rotate the knob with the beginning of 0 0 means there have no hot start and when slowly clockwise rotate the knob the digital wil...

Page 6: ...is the steps for maintaining a Dust removal b Remove dust by professionals with dry and clean compressed air using a compressor or Paper Tiger regularly Meanwhile check inter circuit of welding machin...

Page 7: ...1 1 18 IGBT 6 19 Dual voltage converter plate 1 20 Filter plate is fixed to the aluminum plate 1 21 Intermediate frequency transformer 1 22 Control panel small panel 1 23 Motherboard patch 1 24 Relay...

Page 8: ...to original package s requirement Remember before storage don t forget to clean and seal it with plastic bags Users should maintain the cartons and shock blocks in order to be properly packaged in ne...

Page 9: ...ga ninguna parte del cuerpo al mismo tiempo a los terminales de salida positiva y negativa de soldadura sin protecci n aislada IMPORTANTE Este manual de funcionamiento le muestra con facilidad c mo in...

Page 10: ...nes de ventilaci n y extracci n Prohibir a los no profesionales cambiar o reemplazar el soldador Dado que el soldador posee fuertes frecuencias electromagn ticas y de radio las personas con marcapasos...

Page 11: ...a la red de lo contrario atenerse a las consecuencias Polaridad del electrodo ver imagen de arriba Conecte el enchufe r pido con portaelectrodos al terminal positivo y luego apri telos en sentido hor...

Page 12: ...as del reloj gire la perilla con el comienzo de 0 0 significa que no hay arranque en caliente y cuando gire la perilla lentamente en el sentido de las agujas del reloj el digital crecer m s la pantall...

Page 13: ...liminaci n del polvo b Quite el polvo con aire comprimido seco y limpio usando un compresor regularmente Mientras tanto verifique el circuito de la m quina de soldar regularmente y aseg rese de que el...

Page 14: ...lgado El conector esta aflojado La capacidad de energ a no es lo suficientemente grande Proceso de soldadura PELIGRO ADVERTENCIA Debido a que la m quina tiene la funci n de prohibir la conmutaci n de...

Page 15: ...a 1 2 Carcaza 1 3 Panel frontal 1 4 Perilla del potenci metro 1 5 Panel de control 1 6 Panel frontal 1 7 Piso 1 8 Toma r pida 2 9 Salida de cobre fila 1 1 10 Salida de cobre fila 2 1 11 Diodo de recup...

Page 16: ...nto debe mantenerse seco con buena circulaci n de aire y sin gas o polvo corrosivo La temperatura debe mantenerse entre 25 C y 55 C y la humedad relativa debe ser inferior al 90 Si los productos a n n...