background image

3

INSTALLATION

Connection

   • The welder should be placed in dry and dusty

      surrounding where there is no corrosive chemicals,

      flammable, explosive gases.
   • Avoid direct sunlight and rain. And maintain the ambient 

      temperature ranging from -10º C to 40º C
   • The space of 50 cm should be left around the equipment.
   • If indoor ventilation is not good enough, the ventilation

      exhaust device should be installed.

Power Source Connection

Access the back panel (power source cable) to the power

supply which is equipped with circuit breakers and grounding

line (grid), and it is strictly prohibited that ground wire is

connected to the grid, otherwise bear your own

consequences.

Electrode Polarity (see above picture)

Connect the quick plug with electrode holder to the positive

terminal and then tightened them up clockwise.

Workpiece Connection

Connect the quick plug with earth clamp to the negative

terminal on the front panel below. And then tighten them up. 

Access the earth clamp to the workpiece.

Welding torch

Work piece

Grounding cable

Installation Diagram

                    It is forbidden to connect

the workpiece to the welder with iron

or other poor conductors. 

WARNING

OPERATION INSTRUCTION

1. Digital display 
2. High temperature 
3. Knob 
4. Negative terminal
5. Positive terminal
6. The power cor
7. Switch 

NOTES: The case protection class is

IP21S. Finger or round bars especially

metal rod must be less than 12.5 mm and

it can not be inserted into the welder.

Also you can not press it heavily.

1

2

3

4

5

7

6

Summary of Contents for KN INW-130

Page 1: ...KN INW 130 Inverter welding machine130A Soldadora tipo inversora MMA TIG LIFT...

Page 2: ...ated protection Cautions MMA Inverter DC Arc welder is a kind of electronic product which makes its components more easily damaged While replacing or modulating the strength should not be too much in...

Page 3: ...se from welding process Altitude must be less than 1km Keep good ventilation at a distance of 50cm around Put it in somewhere the speed of wind not less than 1m s Input Power Power supply waveform sho...

Page 4: ...own consequences Electrode Polarity see above picture Connect the quick plug with electrode holder to the positive terminal and then tightened them up clockwise Workpiece Connection Connect the quick...

Page 5: ...epair Once you do not have the ability to check it kindly contact with manufacturer to acquire the service and support of technology The following is the steps for maintaining a Dust removal b Remove...

Page 6: ...e has the function of prohibit switching power supply in rapid succession within a short period of time for switching on and off The power will not open then the indicator light is not on or the fan d...

Page 7: ...rt column 2 1 18 Radiator 4 1 19 IGBT 2 20 Radiator 1 21 Rectifier bridge 1 22 Relay 1 23 Fan 1 24 Fan net 1 25 Rear panel 1 26 Plastic plate 1 27 Ship type switch 1 28 Eletrolytic capacitor 4 D e s c...

Page 8: ...ity must be lower than 90 If the products are still needed to continue storing after stripping repacking should be carried out according to original package s requirement Remember before storage don t...

Page 9: ...arco a trav s de la ventana de la mascarilla No exponga ninguna parte del cuerpo al mismo tiempo a los terminales de salida positiva y negativa de soldadura sin protecci n aislada Precauciones La sold...

Page 10: ...ento 25 C 55 C Humedad relativa del aire 40 C 50 20 C 90 El polvo cidos gases corrosivos y sustancias en el aire ambiente deben estar por debajo del nivel normal excepto los del proceso de soldadura L...

Page 11: ...Acceda al panel posterior cable de la fuente de alimentaci n a la fuente de alimentaci n que est equipada con disyuntores y l nea de conexi n a tierra red y est estrictamente prohibido que el cable d...

Page 12: ...o pegado Eliminaci n de escoria Despu s de terminar el trabajo debe eliminar la escoria con herramientas espec ficas para eliminar residuos PELIGRO ADVERTENCIA La escoria de soldadura no debe eliminar...

Page 13: ...dor Contactar con el proveedor 1 Indicador anormal 2 Perilla rota 3 El ventilador del motor no funciona o la velocidad del rotaci n es baja 4 Sin voltaje de circuito abierto 5 El cable del portaelectr...

Page 14: ...DIAGRAMA 13 Inverter welding machine130A Soldadora tipo inversora MMA TIG LIFT KN INW 130...

Page 15: ...tes mencionados anteriormente son solo para su referencia Si hay algo diferente con la m quina real por favor considerelo como equipo original DIAGRAMA DE INTERCONEXI N Esquema del circuito del soldad...

Page 16: ...nto debe mantenerse seco con buena circulaci n de aire y sin gas o polvo corrosivo La temperatura debe mantenerse entre 25 C y 55 C y la humedad relativa debe ser inferior al 90 Si los productos a n n...

Reviews: