background image

2

SAFETY

     • In some areas, there is no severe vibration.
     • Make sure no interference will be caused to

        the surrounding in the welding area.
     • Whether the power supply capacity is sufficient to allow

        the welder to work normally or not. And a safety

         protection device should be equipped in the input power.
     • Prevent it from dumping if the welder is put in the place

        of over 10°incline.

Security Check

The following items must be checked up by the operator each

time before access to the power source.
     • Make sure the power socket is reliably grounded.
     • Make sure the output terminals are well connected

        without short circuit.
     • Make sure output and input cables are perfect with

        no exposure.

                    Disconnect the power source before

 servicing it. Contact with the manufacturer or agent

immediately to acquire the service and support

skills when users do not have the ability to repair it. 

WARNING

The welding machine must be inspected by professionals at 

regular time (not exceed 6 months). The contents as follow:
     • Whether the electronic components are loosed or not

        and dust removal must be conducted.
     • Whether the panel mounted on the device should be able

        to guarantee the normal implementation of the machine.
     • Whether the input cables are damaged or not. If yes, 

        safe handling must done.

TECHNICAL DESCRIPTION

Environment

     • Working temperature: -10ºC ~ 40ºC
     • Transportation and storage: -25ºC ~ 55ºC
     • Relative air humidity: 40º C≤50%; 20º C≤90%.
     • The dust, acids, corrosive gases and substance in 

        the ambient air must be lower normal level except

        those from welding process.
     • Altitude must be less than 1km
     • Keep good ventilation at a distance of 50cm around.
     • Put it in somewhere the speed of wind not

        less than 1m/s.

Input Power

     • Power supply waveform should be sine wave and

        frequency fluctuations with less than +-1% of its rating.
     • The fluctuations of input voltage must be

        lower than +-10% of the rated value.

Equipment Principle

AC-50/60 Hz

High voltage

Low amperage

DC-Rippled

High voltage

Low amperage

AC-20,000 Hz

Low voltage

High amperage

DC-Rippled

Low voltage

High amperage

DC-Smooth

High voltage

Low amperage

AC-20,000 Hz

High voltage

Low amperage

DC-Smooth

Low voltage

High amperage

NOTES: This is inverter technology. The main part as follow:
Rectifier     Filter     IGBT     Transformer     Rectifier     Choke

Equipment Structure

Working The MMA Inverter DC MMA Welder uses portable

cabinet structure: the upper part of front panel has been

equipped with welding current adjustment knob, power

indicator (green), abnormal indicator (yellow). The output

 terminal is fitted with quick connector both “+” and “-”. 

The back panel owns power switch, motor fan, input power

cable. The inside body of the machine includes PCB main 

board, electronic components, radiator etc.

Parameter

Standard

     • EN 60974-1: Arc Welding Machine Standards
     • JB / T 7824: Technical Conditions of Inverter

        Arc Welding Rectifier
     • GB 4208: Protection Class (IP Code)

Symbol Chart

Note that only some of these

symbols will appear on your model.

A

V

3

On

Off

Dangerous

voltage

Increase / Decrease

AC auxiliary

power

Fuse

Amperage

Voltage

Thee phase

SMAW

GTAW

Wire feed

function

Hz

f

+

1

X

Hertz

(cycles / sec)

Direct current

(DC)

High

Temperature

Welding gun

Positive earth

Frequency

Negative

Positive

Line

Single phase

Duty cycle

GMAW

Summary of Contents for KN INW-130

Page 1: ...KN INW 130 Inverter welding machine130A Soldadora tipo inversora MMA TIG LIFT...

Page 2: ...ated protection Cautions MMA Inverter DC Arc welder is a kind of electronic product which makes its components more easily damaged While replacing or modulating the strength should not be too much in...

Page 3: ...se from welding process Altitude must be less than 1km Keep good ventilation at a distance of 50cm around Put it in somewhere the speed of wind not less than 1m s Input Power Power supply waveform sho...

Page 4: ...own consequences Electrode Polarity see above picture Connect the quick plug with electrode holder to the positive terminal and then tightened them up clockwise Workpiece Connection Connect the quick...

Page 5: ...epair Once you do not have the ability to check it kindly contact with manufacturer to acquire the service and support of technology The following is the steps for maintaining a Dust removal b Remove...

Page 6: ...e has the function of prohibit switching power supply in rapid succession within a short period of time for switching on and off The power will not open then the indicator light is not on or the fan d...

Page 7: ...rt column 2 1 18 Radiator 4 1 19 IGBT 2 20 Radiator 1 21 Rectifier bridge 1 22 Relay 1 23 Fan 1 24 Fan net 1 25 Rear panel 1 26 Plastic plate 1 27 Ship type switch 1 28 Eletrolytic capacitor 4 D e s c...

Page 8: ...ity must be lower than 90 If the products are still needed to continue storing after stripping repacking should be carried out according to original package s requirement Remember before storage don t...

Page 9: ...arco a trav s de la ventana de la mascarilla No exponga ninguna parte del cuerpo al mismo tiempo a los terminales de salida positiva y negativa de soldadura sin protecci n aislada Precauciones La sold...

Page 10: ...ento 25 C 55 C Humedad relativa del aire 40 C 50 20 C 90 El polvo cidos gases corrosivos y sustancias en el aire ambiente deben estar por debajo del nivel normal excepto los del proceso de soldadura L...

Page 11: ...Acceda al panel posterior cable de la fuente de alimentaci n a la fuente de alimentaci n que est equipada con disyuntores y l nea de conexi n a tierra red y est estrictamente prohibido que el cable d...

Page 12: ...o pegado Eliminaci n de escoria Despu s de terminar el trabajo debe eliminar la escoria con herramientas espec ficas para eliminar residuos PELIGRO ADVERTENCIA La escoria de soldadura no debe eliminar...

Page 13: ...dor Contactar con el proveedor 1 Indicador anormal 2 Perilla rota 3 El ventilador del motor no funciona o la velocidad del rotaci n es baja 4 Sin voltaje de circuito abierto 5 El cable del portaelectr...

Page 14: ...DIAGRAMA 13 Inverter welding machine130A Soldadora tipo inversora MMA TIG LIFT KN INW 130...

Page 15: ...tes mencionados anteriormente son solo para su referencia Si hay algo diferente con la m quina real por favor considerelo como equipo original DIAGRAMA DE INTERCONEXI N Esquema del circuito del soldad...

Page 16: ...nto debe mantenerse seco con buena circulaci n de aire y sin gas o polvo corrosivo La temperatura debe mantenerse entre 25 C y 55 C y la humedad relativa debe ser inferior al 90 Si los productos a n n...

Reviews: