2

SAFETY REGULATIONS

lt must realize safe

grounding.

The generator surface has

high temperature, avoid

scalding. Pay attention

to the warnings on

the generating set. 

WARNING

WARNING

DANGER

DANGER

General safety information

 

The generator produces enough electric power to

cause a serious shock or electrocution if misused. 

 

    • Operator should put on personal protective

       equipment during operation and maintenance.
    •  The installation and major repair work shall be carried

       out only by specifically trained personnel.

    •  Do not use the generator underground.
    •  Do not use the generator under an explosive condition.

    •  lt is prohibited to use bare wire to connect power supply

       to the electric equipment directly, use the plug that fits

       local regulations.
    •  In equipment operation, do not touch wire or live parts

       of the equipment. Never touch the machine with wet

       hands or electrical shock will occur.
    •  In equipment operation, keep children certain safe

       distance from the generator.
    •  In equipment operation, strictly prohibit assembling

       and disassembling any parts.
    •  lt is suggested to realize tandem connection of a ground

       fault circuit interrupter (GFCI) when the power supply is

       out to guarantee safety.
    •  Externa! electric accessory (including cable and plug 

       interconnecting piece) shall have no fault. Electric shock 

       defend depends on the breaker, especially the matching

       between breaker and generator. During replacement of

       the breaker, only that with the same rating and

       performance features can be adopted. Contact local

       dealers or the after-sales service center for support.
    •  In case of using lengthening wire or mobile power

       distribution cabinet, overall length of the wire with cross

       section of 1.5mm

2

 shall be no longer than 60 m, and that

       of 2.5mm

2

 shall be no longer than 100 m.

    •  Avoid connecting the generator in parallel with any

       other generator.

DANGER

Fuel of the machine is flammable, which will

generate high temperature and easily cause fire

during operation. 

 

    • lt is strictly prohibited to add fuel during equipment

       operation.
    •  In case of adding fuel, keep far away from tire brand,

       no smoking.
    •  In case of adding fuel, do not spill fuel on the equipment.
    •  As to accidental spilling, use cotton cloth to clean it. Start

       the equipment after spilt fuel evaporates completely.
    •  In

 operation, make sure that there is no flammable

       substance within 2 meter range, and no flammable

        substance will approach the equipment. Avoid placing any

       flammable materials near the exhaust outlet during

       operation.
    •  In case of long-term nonuse, take out the fuel from fuel

       tank and store it safely.
    •  lf you swallow any fuel, inhale fuel vapor, or allow any to

       get in your eyes, see your doctor immediately. lf any fuel

       spills on your skin or clothing, immediately wash with

       soap and water and change your clothes.
    •  When operating or transporting the machine, be sure it

       is kept upright. lf it tilts, fuel may leak from the

       carburetor or fuel tank.
    •  Do not throw the residue fuel and used motor oil into the

       trash or pour it onto the ground. We suggest you take

       used oil in a sealed container to your local recycling

       center or service station for reclamation.

This equipment contains high speed revolving parts, 

which will harm human body. 

 

CAUTION

    •  In equipment operation, do not approach it and strictly

       prohibit touching revolving parts.
    •  In equipment operation, do not lift or move it. Move it

       only after equipment completely stopped.
    •  In equipment operation, observe surroundings. Make

       sure no articles are involved into the equipment.

    •  Do not place heavy weight on the equipment.
    •  The wheel is for easy moving of the equipment. Do not

       use it for long distance moving, otherwise it will be

       damaged.
    •  Do not exceed rated power of the equipment in

       operation; otherwise, its service life will be shortened.

       Power of common household appliances is shown on

       Page 9, 10 in details.
    •  Please maintain the equipment according to the

       requirements so as to prolong its service life. Refer to

       Page 10 for details.
    •  Prevent duct from entering into the equipment during

       operation or storage.

NOTICE

Operating requirements 

 

Summary of Contents for KN GEN-30

Page 1: ...KN GEN 65 6 500 W KN GEN 80 8 000 W Portable generators Generadores port tiles We invite you to read the user manual before operating your equipment Lo invitamos a leer el manual del usuario antes de...

Page 2: ...ation or maintenance of the generator the operator should lt is impossible for manufacturers to predict all hazardous circumstances that may occur for this reason warnings in this manual and caution s...

Page 3: ...cause fire during operation lt is strictly prohibited to add fuel during equipment operation In case of adding fuel keep far away from tire brand no smoking In case of adding fuel do not spill fuel on...

Page 4: ...ier and safer Glossaries Symbol Name Meaning V A Hz W RPM PF G1 Volt Ampere Hertz Watt Power factor Electric risk Revolutions per minutes Performance rate Read instructions Safety warning Voltage Curr...

Page 5: ...ng mode Starting mode Displacement Net weight Uncertainty L x W x H mm Capacity of fuel tank Valve clearance inlet outlet 0 6 L 196 cc 389 cc 420 cc 1 1 L 1 1 L Weight only for reference Overall dimen...

Page 6: ...oving the generator in a short time Battery optional It is for starting up the generator In case of nonuse for three months charge it Oil filler cap Oil drain bolt Foot It is for measurement of engine...

Page 7: ...able SAE TEMP AMBIENT TEMPERATURE Filling fuel No exceeding this level Open the fuel tank cap and fill gasoline the fuel leveler s position will display gasoline mass in the fuel tank and take care th...

Page 8: ...t load for 5 seconds and then turn on the choke valve switch WAIT 5 sec Connect to load Access electric equipment and turn the circuit breaker to ON Please note that when several loads are used at the...

Page 9: ...a rough road drain the fuel from the generator beforehand NOTE To transport the generator hold the holding part shaded areas in the figure 1 Take care not to drop or strike the generator when transpo...

Page 10: ...specified in the drawing 2 Install the storage battery bracket onto the bracket connection tube 3 Install the storage battery shield onto the bracket connection tube 4 Install the assembled bracket o...

Page 11: ...Wash Wash Replace Readjust Spark plug Valve clearance Cylinder head Fuel tank and strainer Air cleaner Fuel switch sediment cup Fuel tube 1 2 Every 300 hours 2 Every 2 years 2 Every 2 years 2 1 Maint...

Page 12: ...e inlet valve and 0 15 mm for the outlet valve 10 000 DC 10 000D DC The clearances are 0 07 mm for the inlet valve and 0 10 mm for the outlet valve Clean the spark plug Recommended spark plug models F...

Page 13: ...park plug fails The temperature of the engine is too low Turn the switch to the on position The spark plug fails Replace clean oil Drain some oil Replace a socket Add oil The generator can not start N...

Page 14: ...16A AC output 115V 16A Voltage selector V lamp Circuit brecker 10A Ground terminal Engine S W DC terminal DC 12V DC protector 10A Main winding DC diode DC winding Exciter winding Field winding Genera...

Page 15: ...C output 110V 32A AC output 110V 32A Circuit brecker 22A V lamp Main winding DC winding DC protector 10A DC diode DC terminal DC 12V Engine S W Engine block Engine block Oil level switch Oil alert Spa...

Page 16: ...nal Engine S W V lamp DC protector 10A DC diode DC terminal DC 12V Circuit brecker 22A Fuse 5A Main winding DC winding Exciter winding Field winding Generator block Fuel cut winding Fuse 5A A V R Engi...

Page 17: ...n o mantenimiento del generador el operador debe Es imposible para los fabricantes predecir todas las circunstancias peligrosas que pueden ocurrir por esta raz n las advertencias en este manual y las...

Page 18: ...antemente prohibido agregar combustible durante la operaci n del equipo En caso de agregar combustible mant ngase alejado de la marca de neum ticos no fume En caso de agregar combustible no derrame co...

Page 19: ...o Amperio Hercios Vatio Factor de potencia Riesgo el ctrico Revoluciones por minuto Tasa de rendimiento Leer instrucciones Advertencia de seguridad Voltaje Corriente Frecuencia 1Hz 60 r min Energ a Ve...

Page 20: ...do Modo de inicio Desplazamiento Peso neto Incertidumbre largo x alto x fondo mm Capacidad del tanque de combustible Juego de v lvulas entrada salida 0 6 L 196 cc 389 cc 420 cc 1 1 L 1 1 L Peso solo c...

Page 21: ...cional Es para mover el generador en poco tiempo Bater a opcional Terminal de puesta a tierra Es para poner en marcha el generador En caso de no uso durante tres meses c rguelo Es para hacer que el ge...

Page 22: ...la tapa del tanque de combustible y llene gasolina la posici n del nivelador de combustible mostrar la masa de gasolina en el tanque de combustible y tenga cuidado de que la posici n m xima de combus...

Page 23: ...da el interruptor de la v lvula de estrangulamiento ESPERAR ESPERAR 5 SEG 5 SEG Conectar para cargar Acceda al equipo el ctrico y encienda el disyuntor Tenga en cuenta que cuando se utilizan varias ca...

Page 24: ...identado drene el combustible del generador de antemano NOTA Para transportar el generador sostenga la pieza de sujeci n reas sombreadas en la figura 1 Tenga cuidado de no dejar caer o golpear el gene...

Page 25: ...0 1000 1000 5 50 5 50 120 Electrodom sticos Foco ahorradora de energia Olla el ctrica Equipo electrico Potencia nominal W Potencia de arranque W Computadora 400 50 300 100 100 400 Electrodom sticos DV...

Page 26: ...ndro Tanque de combustible y colador Filtro de aire Taza de sedimentos del interruptor de combustible Tubodecombustible 1 2 Cada 300 horas 2 Cada 2 a os 2 Cada 2 a os 2 1 El mantenimiento debe realiza...

Page 27: ...para la v lvula de salida 10 000 DC 10 000D DC Las holguras son de 0 07 mm para la v lvula de entrada y de 0 10 mm para la v lvula de salida Limpiar la buj a Modelos de buj as recomendados F7RTC y F7...

Page 28: ...or es incorrecto La holgura de la v lvula est fuera de los l mites La buj a falla La temperatura del motor es demasiado baja Gire el interruptor a la posici n encendido La buj a falla Reemplace por ac...

Page 29: ...Selector de voltaje L mpara V Circuito disyuntor 10A Terminal de tierra SW del motor Terminal de CD CD 12V Protector CD 10A Devanado principal Diodo de CD Devanado de CD Devanado excitador Campo airo...

Page 30: ...110V 32A Disyuntor 22A L mpara V Devanado principal devanado de CC Protector CD 10A Diodo de CD Terminal de CD DC 12V SW del motor Bloque de motor Bloque de motor Interruptor de nivel de aceite Alert...

Page 31: ...r CD 10A Diodo de CD Terminal de CD CD 12V Disyuntor 22A Fusible 5A Devanado principal Devanado de CC Devanado excitador Campo airoso Bloque generador Bobinado de corte de combustible Fusible 5A A V R...

Page 32: ...www knova com mx...

Reviews: