Testing Handle Operation:

Briefly test press operation as follows 

BEFORE using. With handle on the release 

valve turning clockwise or counter clock wise 

allows the hydraulic jack to be raised apply 

pressure and lowered reduce pressure. To 

raise the jack, twist handle clockwise until 

it is firm. Do not force or tighten beyond 

this point. Take handle from release valve 

and place in handle base. Pump handle a 

few times to raise the jack about halfway. 

If jack does not begin to rise after a few 

pumps, check to make sure the release 

valve is tight. With hydraulic jack raised, 

place handle on release valve twist handle 

slowly counterclockwise to lower jack. A 

normal hissing sound may be heard as jack 

lowers and pressure in hydraulic cylinder is 

released.

 

Using the Pipe Bender:

This hydraulic pipe bender comes with eight 

bending die’s to allow for wide variety of 

pipe diameters to be bent. The pipe bender 

is designed to bend heavy water pipe and 

galvanized pipe 13 mm. through to 76 mm.

1.

 Place the pipe bender on a smooth

    surface and clamp or bolt into position.
2. Select the correct die for the diameter of 

    pipe to be bent. The wrong die with cause

    the pipe to kink or crease.

3.

 Adjust the guide rollers to the desired

    distance to achieve the angle of bend

    required.

4.

 Insert the pipe into pipe bender - for large

    diameter or long lengths of pipe two

    people are required one to balance the

    pipe and the other to operate the pipe

    bender.

5.

 Turn jack handle completely clockwise on

    the release valve. Place handle in sleeve

    and slowly pump handle until die pushes

    the pipe is just firm against the guide

    rollers.

6.

 Inspect position of pipe, die, guide rollers

    and free ends of pipe will not foul or 

    impact on anything or anyone.

7.

 Pump handle until pipe bender has

    completed the required operation. Pay

    attention to work piece position as pipe

    bender is applying pressure to be sure

    there is no danger of slipping off or

    forcing out of the work piece.

8. 

If pipe starts to kink or crease is may

    help to fill the pipe with sand and securely

    cap both ends.

9.

 SLOWLY turn hydraulic ram release valve

    counterclockwise to release pressure. Be

    aware that the work piece may move

    when pressure is released.

    valve counterclockwise to release

    pressure. Be aware that the work piece

    may move when pressure is released.

Warning:

The hydraulic pipe bender is not a vice and 

no work should be undertaken on the work 

piece while being held by the pipe bender

failure to comply with this instruction 

creates a potentially hazardous working 

environment. Do not move the pipe bender 

wherever practical the press should be 

bolted to the ground. Never place any part 

of your body through the frame or under any 

of the moving parts. The forces applied by 

this pipe bender are large if the die or guide 

rollers are not properly installed excessive 

forces can be generated which may lead to 

property damage or personal injury.

Maintenance and Storage

Important Note:

When adding or replacing oil, always use a 

good grade Hydraulic Oil. Avoid mixing types 

of oil. DO NOT use Brake Fluid, Alcohol, 

Glycerin, Detergent, Motor Oil or Dirty Oil, 

Improper fluid can cause serious internal 

damage to hydraulic ram.

Adding Oil:

With ram fully lowered & on level surface, 

remove Air Vent Valve. Oil level should be 

approx 12 mm below valve hole. If low, add 

oil as needed then close air vent valve.

Replacing Oil:

For better performance & longevity, replace 

oil supply once a year. To drain oil, open Air 

Vent Valve and loosen the release Valve by 

turning handle counterclockwise. BE VERY 

CAREFUL not to permit dirt or foreign 

matter to get into the system. Close release 

valve by turning handle clockwise, fill with 

good grade Hydraulic Oil close Air Vent 

Valve wipe away any spilt fluid. Test

hydraulic ram before applying a load.

Cleaning:

Hydraulic jack should be wiped clean with 

soft cloth only. Do not use gasoline,

kerosene, or other such solvents or any 

abrasive cleanser as cleaning agents and 

solvents will cause deterioration of the 

hydraulic seals.

Summary of Contents for KN 7410-16

Page 1: ...Hydraulic pipe bender Doblador hidráulico para tubo KN 7410 16 16 TONELADAS TONS ...

Page 2: ...ly Follow this procedure each time the pipe bender is used to help prevent property damage and or serious injury SPECIFICATIONS 1 Thoroughly inspect pipe bender for damage or 1 Thoroughly inspect pipe bender for damage or wear before each use Briefly test operation of unloaded hydraulic jack before using to bend any job If jack is damaged or is malfunctioning DO NOT USE until the problem is correc...

Page 3: ...nger of slipping off or forcing out of the work piece 8 If pipe starts to kink or crease is may help to fill the pipe with sand and securely cap both ends 9 SLOWLY turn hydraulic ram release valve counterclockwise to release pressure Be aware that the work piece may move when pressure is released valve counterclockwise to release pressure Be aware that the work piece may move when pressure is rele...

Page 4: ...pt any repairs or replacing of parts Any modifications to this Pipe bender except those performed by the manufacturer or their designee will void all warranties both written and implied EXPLODED DIAGRAM ITEM DESCRIPTION QTY 09 BED SPRING 2 10 SUSPENSION PLATE 1 11 1 2 BENDING DIE 1 12 3 4 BENDING DIE 1 13 1 BENDING DIE 1 14 1 1 4 BENDING DIE 1 15 1 1 2 BENDING DIE 1 16 2 BENDING DIE 1 17 2 1 2 BEN...

Page 5: ... Inspeccione minuciosamente el doblador ESPECIFICACIONES de daños o desgaste antes de cada uso Brevemente haga una operación de prueba del gato hidráulico sin carga antes de usarlo para doblar cualquier trabajo Si el gato está dañado o no funciona bien no lo utilice hasta que se corrija el problema 2 Consulte el manual de propietario para las medidas de seguridad el uso correcto y los procedimient...

Page 6: ... plegarse se puede ayudar llenando el tubo con arena tapando bien ambos extremos 9 Gire lentamente la válvula de liberación del gato hidráulico hacia la izquierda para liberar la presión Tenga en cuenta que la pieza de trabajo puede moverse cuando se libera la presión Advertencia El doblador de tubo hidráulico no es un tornillo de banco y ningún trabajo debe realizarse sobre la pieza de trabajo mi...

Page 7: ...eparación o sustitución de piezas Cualquier modificación a este doblador de tubo con excepción de las realizados por el fabricante o su designada anularán todas las garantías tanto escritas como implícitas DIAGRAMA EXPOSIVO NO DESCRIPCION CANT 09 RESORTE 2 10 PLACA DE SUSPENSION 1 11 DADO DOBLADOR DE 1 2 1 12 DADO DOBLADOR DE 3 4 1 13 DADO DOBLADOR DE 1 1 14 DADO DOBLADOR DE 1 1 4 1 15 DADO DOBLAD...

Page 8: ...www knova com mx ...