STAR 14 PELLET BOILER STOVE
17
EN - Rev. 2.1
The following figure describes the meanings of the status signals appearing on the display left side (1st LED SERIES).
!
The meanings of the status signals appearing on the top right side of the display are described below (2nd LED
SERIES).
-
LED 1: the LED lights up when the daily programme of the on off settings is active.
-
LED 2: the LED lights up when the weekly programme of the on off settings is active.
-
LED 3: the LED lights up when the weekend programme of the on off settings is active.
-
LED 4: the LED lights up (flashing) when the operation parameters are being edited.
-
LED 5: the LED lights up when the summer function is active (Not used on this product).
-
LED 6: the LED lights up when the winter function is active.
-
LED 7: the LED is not currently used.
The following diagram shows the display when setting or programming operating parameters.
Set
!
1
2
3
4
5
6
The INPUT area shows the entered programming values.
The MENU LEVEL area shows the current parameter/menu level.
The DIALOGUE area displays the meaning of the current parameter/menu.
ROOM THERMOSTAT: the LED is on when the thermostat contact is open.
PROGRAMMABLE THERMOSTAT: the LED lights up when at least one start-up and switch-off program is active.
IGNITION HEATING ELEMENT: the LED is on when the ignition heating element is active.
SCREW FEED: the LED lights up when the pellet loading gear motor is started.
FLUE GAS EXTRACTOR: the LED lights up when the flue gas extractor is active.
DHW FLOW SWITCH: the LED lights up when the DHW flow switch contact is closed (which means there is
demand for hot water). LED only works when the flow switch is connected
PUMP: the LED lights up when the system circulation pump is active.
ALARM: the LED lights up when the boiler is in a state of alarm.
1
2
3
4
5
6
7
DIALOGUE
MENU LEVEL
On
M - 2 - 2 - 01
CHRONO
DAY
INPUT