Example:
In this condition...
...if you want to operate the central heating cooker with KLOVER remote control room temperature only::
enable the room sensor on the remote control (stove settings menu +> Enable room sensor -> ON)
disable the boiler thermostat contact on the central heating cooker display (menu 4 enable contact ->
OFF)
In this case, the central heating cooker first enters economy mode operation, and then automatically
switches off when the desired room temperature (detected with KLOVER remote control) is reached.
...if you want to operate the central heating cooker with KLOVER remote control room temperature and with
boiler thermostat:
enable the room sensor on the remote control (stove settings menu +> Enable room sensor -> ON)
enable the boiler thermostat contact on the central heating cooker display (menu 4 enable contact ->
ON)
In this case, the central heating cooker first enters economy mode operation, and then automatically
switches off when both temperatures have been reached.
...if you want to operate the central heating cooker with the boiler temperature only:
disable the room sensor on the remote control (stove settings menu +> Enable room sensor -> OFF).
The room sensor is automatically disabled if no external remote control is connected.
enable or disable the boiler thermostat contact on the central heating cooker display (menu 4 enable
contact -> ON/OFF)
In this case, the central heating cooker first enters economy mode operation, and then automatically
switches off when the boiler temperature (measured with an external thermostat immersed in the boiler) has
been reached. This may be a viable solution to heat DHW in summer.
...if you do not want to operate the central heating cooker with external thermostats but only with the water
temperature in the heating system:
disable the room sensor on the remote control (stove settings menu +> Enable room sensor -> OFF).
The room sensor is automatically disabled if no external remote control is connected.
enable or disable the boiler thermostat contact on the central heating cooker display (menu 4 enables
contact -> ON/OFF). The contact must obviously be bridged (provided for in the factory).
Only when reaching the temperature set in
“SET H2O”
or
“SET DHW”
does the central heating cooker
enter economy mode operation.