Summary:
CASE
REMOTE CONTROL
ROOM PROBE
ROOM THERMOSTAT
CONTACT
ACTION
1
OFF
OFF
Works with room thermostat contact
2
OFF
ON
Works with room thermostat contact
3
ON
OFF
Works with remote control room probe
only
4
ON
ON
Works with remote control room probe
and room thermostat contact
5. Menu 05
– 3-Way Valve Threshold
Allows setting temperature threshold for switch-over of 3-Way motorised valve installed in DHW
system. Change-over happens after 30" from reaching set temperature and with hysteresis of 2°C.
Example:
3-Way Valve Threshold = 55°C
The valve opens after 30" from reaching 55°C.
Valve closes if 52°C is reached.
6. Menu 06
– Acoustic alarm
It allows enabling or disabling acoustic signal in case of alarm. Acoustic signal is only present on
boiler board and not on external remote control.
7. Menu 07
– Initial load
It allows pre-loading pellet for
90” with boiler off and cold. Start using key 1 and stop using key 4. It
can be useful if the boiler is ignited once the tank has been fully emptied or it is the first time it is
filled.
8. Menu 08
– Stove state
It allows displaying the instantaneous boiler's state showing the state of the various devices
connected to it. Different pages displayed in succession are available. As the reported data is
reserved to Technical Assistance Centre we recommend not accessing this menu.
9. Menu 09
– Technical calibrations
It allows to access all that reserved to Technical Assistance Centre. Access is protected by access
key. Unauthorised access can cause serious damage to the equipment, to persons and to the
environment.