28
EN
G
L
ISH
WHAT HAPPENS IF..
…the pellets do not ignite
In case of ignition failure. The
“IGNITION FAILURE“
alarm message appears.
Cancel the alarm by pressing button 3 for a few seconds then restore the stove to the standard conditions.
...the fire door is improperly opened or closed
In case the door is open or closed improperly, the gearmotor cannot be powered electrically, therefore the
stove does not switch on. If the fire door is opened during normal operation, the stove burns all the pellets in
the brazier before activating the
“NO PELLETS”
alarm.
...the flue is dirty, blocked or not incorrectly manufactured
In case the flue is dirty, blocked or incorrectly manufactured, the gearmotor cannot be powered electrically
thus the stove will not switch on. If the flue gets obstructed during normal operation, the stove will burn all the
pellets in the brazier before activating the
“DEPRESS.-FAILURE”
alarm.
…the pellet tank goes in over-temperature
In case of over-temperature, the gearmotor is not electrically powered as the manual rearm thermostat
intervenes. If this occurs while the stove is operating, the latter enters the
“SAFETY TEMP.”
alarm mode. It is
therefore necessary to rearm the thermostat before switching the stove on again.
...lack of power (blackout)
If power lacks for a period of time inferior to parameter Pr48, once it returns, the stove immediately restores
the operating state it had before the blackout (at the same pre-set working power).
If power lacks for a period of time greater than parameter Pr48, once it returns, the stove enters the
“BLACKOUT”
alarm mode and performs the entire switch-off cycle until it cools down.