24
EN
G
L
ISH
TIP:
in order to avoid confusion and any undesired switching on/off operations, only activate a single programme
at a time if you do not know exactly what you desire obtaining.
Deactivate the daily programme if you wish to use the weekly programme instead. Always keep the weekend
programme deactivated when using the weekly programmes 1, 2, 3 and 4.
Only activate the weekend programme after having deactivated the weekly programme.
3. Menu M3
– LANGUAGE
Allows for selecting the dialogue language from the available ones (Italian, English, French, German).
4. Menu M4
– STAND-BY
If set to
OFF
(with buttons 1 or 2) it allows for excluding the stove switch-off if the temperature set in the
"SET TEMPERATURE" function has been reached. The working power will nonetheless be modulated
according to the "MODULATE" value.
If set to
ON
(with buttons 1 or 2) the stove will enter the modulation mode and/or switch off if the temperature
set in the "SET TEMPERATURE" function has been reached.
5. Menu M5
– BUZZER
Allows for enabling or disabling acoustic signal in case of alarm.
6. Menu M6
– FIRST LOADING
Allows for performing pellet pre-loading for 90” with the stove off and cold. Start the function with button 2
and stop with button 3. It may be useful in case the stove is switched on after the tank has been completely
emptied, or when it is filled for the first time.
7. Menu M7
– STOVE STATUS
It allows for viewing the instantaneous stove state, by showing the state of the various devices connected to
it. Several pages are displayed in succession. As the reported data is reserved for the Technical Assistance
Centre, we recommend not accessing this menu.
Example of
VISUALISED STATE
MEANING
3,1 “
Screw feed gearmotor work time
52’
Time out
Toff
Thermostat state
112°
Flue gas temperature
1490
Flue gas extractor speed
The TIME-OUT state indicates:
during the phase:
MEANING
PELLET LOADING
Maximum time remaining in the PELLET LOADING phase
FIRE PRESENT
Time remaining in the FIRE PRESENT phase
WORK
Time remaining for performing the BRAZIER CLEANING
phase
8. Menu M8
– TECHNICAL CALIBRATIONS
Allows for accessing all data reserved for the Technical Assistance Centre. Access is protected by an access
key. Unauthorised access may cause severe damage to the device besides harming people and the
environment.
9. Menu M9
– EXIT
Allows for exiting the user menu.