3.Quick start
3.1.
Basic settings
For example, let us you have a pipe of 200mm outer diameter
、
4mm pipe thickness, measuring medium is water,
Pipe Material is PVC with no Liner, These parameters should be operated as follows:
Step1. Pipe Size Settings
Find M10; enter the pipe size, the outer diameter of
the pipe and the pipe thickness.
Press the “ Enter” to confirm.
OD200.0mm
Step2. Pipe Material
Use “
↓
” to switch to select the material of the
pipe.
Press the “ Enter” to confirm.
SizeM.
Step 3. Water Temperature
Find M12, select the temperature of the water,
M12Medium*R
temperature should be 0-80 deg. C.
Press the “ Enter” to confirm.
Note: Room temperature is 25 deg.C
WTMP
20(
。