6
filtering unit
STRONG
-
5000
-
S
15.10.2019
Fig. No.3
– Optional equipment
Fig. No.4
– Pneumatic installation
6. Assembly and Start-up
Generally, STRONG-5000-S filtering unit is developed for use in closed room (indoor applica-
tion), but it can also be applied outdoors as the motor is protected by a hood from atmosphe-
ric factors (see Fig. No.2).
Put the appliance
stably on the even floor surface.
Mind that there should be
free access to the
control unit and to the waste container.
Prior to installing check the load carrying capacity of the floor.
The legs
of the STRONG-5000-S device
are divided
(sectioned)
, so the total height of the
device can be reduced for transport
. Right after its delivery
at the
site of use, the legs have
to be assembled by screwing up to the base
(a set of screws/bolts is delivered by KLIMAWENT
S.A.). For the transport time, the appliance is protected with foil and placed on a transport
pallet. Having removed the protective foil, put the filtering unit exactly on the foreseen place
of use (it is advised to use a fork lift).
In the device base there are special guide holes to insert the profiles of the fork lift.
The device is equipped with eye bolt handles to attach the transport ropes for loading /
reloading.
Make connections to the external
compressed air installation 0,6÷0,8 MPa. The
connection point is a connection fitting piece
to the ½” hose. The compressed air should be
free from oil
, humidity and any other impurities.
The connection has to be equipped with
a valve, air filter and a
dewaterer
. All these elements are not delivered along with the device.
During the device preparation for the start-up, supply the power by connecting the cables to
the control unit
according to the enclosed electrical connection diagram.
Connection to the power supply system should be performed exclusi-
vely by an authorized person of testified electrical qualifications.