Klimawent STRONG-5000-S Use And Maintenance Manual Download Page 10

                                   10 

                                                     

filtering unit

  STRONG

-

5000

-

S

        

                      

 

       

15.10.2019

 

   

 

 

 

Fig. No.9  

–  Time chart of work regimes 

NAVIGATION 

The

 UFOx5.1 

controller includes a built-in control keyboard, for setting the work parameters.  

The keyboard is installed on the right side and consists of 6 micro-switches. 

 

 

RETURN  TO  THE  MANUFACTURER’S  SETTINGS 

 

–  press the 

ESC

 button and hold it 

through 10 seconds. 
 
Navigation on the “linear” menu: 

UP

 

– next screen 

DOWN

 

– previous screen

 

 

Navigation on 

the “nested” menu: 

RIGHT

 

– lower level of the menu 

LEFT

 

– higher level of the menu 

 

How to change the editable parameter: 

OK

 

– marking (illumination) of the parameter 

 

RIGHT

LEFT 

– displacing the cursor between the fields that are possible to be marked 

UP

DOWN 

– change the value of the illuminated parameter 

OK

 

– confirm and leave the edition mode

 

ESC

 

– leave the parameters without confirmation 

 

GENERAL  MENU 

 

 

 

Status

 = RUN  

 

Board

 = OK 

 STATUS screen 

 

(Status): 

 

RUN

 – a mode of work 

NSTR

, the 

OUT1

 output is switched on 

 

STOP

 – the state of stop, the 

OUT1

 output is switched off

 

 
  

 (Board): 

 

OK

 – correct state of the functional elements of the board 

UFOv5.1 

 

EO1

 – alarm of the memory of the data 

 

EO2

 – alarm of the sensor of the temperature measuring  

 

EO3

 – alarm of the 

RTC

 clock 

 

 

 

 

 

Summary of Contents for STRONG-5000-S

Page 1: ...nt klimawent com pl www klimawent com pl 804U59 STRONG 5000 S 01 10 2019 EN Contents 1 Introductory Remarks 2 2 Application 2 3 Reservations of Producer 2 4 Technical Data 3 5 Structure and Function 4...

Page 2: ...rective of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06...

Page 3: ...ining viscous and aggressive contaminants as this would cause damage of the filters or forwarding the madia of temperature exceeding 60 C H Sources of ignition e g glowing parts cigarette butts embers...

Page 4: ...nd electromagnetic valves hopper discharge underneath the housing waste container connected with the hopper discharge equipped with castor wheels four legs as a base for the housing connection fitting...

Page 5: ...5 01 10 2019 filtering unit STRONG 5000 S Fig No 2 STRONG 5000 S Structure and dimensions...

Page 6: ...e the appliance is protected with foil and placed on a transport pallet Having removed the protective foil put the filtering unit exactly on the foreseen place of use it is advised to use a fork lift...

Page 7: ...nt that the locks can be bent fully aside and User can open the door widely to the right angle Insert the subsequent filter cartridges onto the slide guides and push them to the wall of the electro va...

Page 8: ...lamp lights continuously to the moment when the failure is fixed Press the S2 STOP button one more time to stop the H3 light yellow lamp H4 signalling of the regeneration of the filters green button S...

Page 9: ...rom short circuit overload and not complete phases function effects over current disconnector F1 protection for the transformer circuit and of the controller over current disconnector F2 protection fo...

Page 10: ...FT higher level of the menu How to change the editable parameter OK marking illumination of the parameter RIGHT LEFT displacing the cursor between the fields that are possible to be marked UP DOWN cha...

Page 11: ...ation stage of the filters STOP the device is being stopped after the alarm vanishes operator needs to delete it ALPR1 alarm signal of low pressure 1 ALPR2 alarm signal of low pressure 2 ALPR3 alarm s...

Page 12: ...1 Sub menu of the settings COMMUNICATION 1 The function is not active in the program version 2 0 up to 2 2 INPUTS OUTPUTS Screen INPUTS OUTPUTS Sub menu of the settings INPUTS OUTPUTS Day Tu hour 10 0...

Page 13: ...activated initial regeneration SWF TEMP REG NONE AL24V akt OFF Screen MODES 2 6 TEMP REG NONE I HEAT I COOL NONE disconnected the controlling with output OUT5 in function of temperature HEAT activated...

Page 14: ...the status at inputs DI0 up to DI3 ALPR akt OFF Cons START OFF Screen MODES 4 6 ALPR AKT OFF and ON OFF blocking of the occurring alarm ALPRi at the inputs DI0 up to DI3 ON alarm ALPRi at the inputs D...

Page 15: ...ve Input DI6 fulfils the same function as the button FILTER S3 on the elevation console DI8 START OFF DI8 STOP OFF Screen MODES 6 6 DI8 START OFF I ON OFF blocking of the possibility of activation by...

Page 16: ...ectro magnetic valves during the status SWF Lsekwen Lon 0 9 cycles Lsekwen Lon number of sequences 4 cycles of pulsing each Time T12 0 5s Ton PowPause 10s Screen SETTINGS 2 6 Time T12 0 1 5 sec Time T...

Page 17: ...lectromagnetic valves StanZas 24V state of the fuse of the transformer 24VAC of the power supply of the electromagnetic valves Time T22 0 5s Lsekwen Loff 02 Screen SETTINGS 4 6 Time T22 1 99sec Time T...

Page 18: ...ro valves AktPoziomWe LO I HI AktPozimWe the level of signal from the input of pressure control is activated Tset 21 0 C Screen SETTINGS 6 6 Tset 10 60 Tset the applied temperature for the controlling...

Page 19: ...atus of the analogue input 0 10V TO status of the outputs of impulses T1 T4 Tb 25 5 0 C StanZas 24 OK Screen INPUTS OUTPUTS 3 3 Tb measuring of temperature on the controller StanZas 24V the state of t...

Page 20: ...larm blocks the sys tem function until the alarm stops After the alarm reason is fixed press the S2 STOP button one more time this will delete the H3 lamp In case of the adjusted parameter Cons STOP O...

Page 21: ...Close the dewatering valve when exclusively clean and dry air is discharging from the installation The construction of the extraction fan and motor guarantees the work of the unit without the routine...

Page 22: ...MPa Repair should be carried out after the fan is switched off and the device is disconnected from the power supply mains 11 Transport and Storage STRONG 5000 S filtering unit has to be transported i...

Page 23: ...energy related products Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Par liament and of the Council with rega...

Page 24: ...24 filtering unit STRONG 5000 S 15 10 2019 NOTES...

Reviews: