11
01.10.2019
filtering unit
STRONG
-
5000
-
S
Tu, 10:00,
MANUAL
status
RUN
=
NSTR
MASTER screen
(Status
RUN
):
STB
– state of initialising the controller’s work, directly after the
power supply is switched on
NSTR
– normal status of work of the fan power supply
RSTR
– readiness (stand-by) status for the switching on the status
RUN
of the
NSTR
status
SWF
– initial regeneration (shaking) of the filters
SKF
– final regeneration stage of the filters
STOP
– the device is being stopped after the alarm vanishes
(operator needs to delete it)
ALPR1
– alarm signal of low-pressure 1
ALPR2
– alarm signal of low-pressure 2
ALPR3
– alarm signal of low-pressure 3
ALPR4
– alarm signal of low-pressure 4
AL24V
– alarm signal of lack of the supply
24VAC
for the
electromagnetic valves
ALRS
– alarm signal from the motor disconnector
(MANUAL):
MANUAL
– mode of continuous work
PROG
– mode of work as a function of time programmer
SETTINGS ->
Screen SETTINGS
Sub-menu of the adjustments group SETTINGS
MODES ->
Screen MODES
Sub-menu of the setting groups MODES