background image

Press this button, could select displaying 

the indoor setting temperature or indoor 

ambient temperature.When the indoor unit 

firstly power on it will display the setting 

temperature, if the temperature's displaying 
status is changed from other status to"      ", 

displays the ambient temperature, 5s later 

or within 5s, it receives other remote control 

signal that will return to display the setting

temperature. if the users haven't set up the 

temperature displaying status,that will 

display the setting temperature.

TEMP button

TEMP

Press this button, Sleep On and Sleep 

Off can be selected. After powered on,

Sleep 

Off is defaulted. After the unit is 

turned off, the Sleep function is canceled. 

After Sleep function set up, the signal of 
Sleep will display. In this mode, the time of

timer can be adjusted. Under Fan and Auto

modes, this function is not available.In

sleep mode, setting temperature is

adjusted automatically.

NOTE: This  remote control is universal, it could be used formany units, some

buttons of this control  which are not available to this unit will not be 
described below.

Names and functions of remote control buttons

BLOW

Set Blow on (the characters of Blow will 

appear)or off (the characters of Blow

disappear ) by pressing this key under

cool or DRY mode. Once energized,

the unit will be defaulted to be Blow off.

This function can not be set under auto,

fan or heat mode, and the characters of

Blow won't appear.

Press this button to select  LIGHT on or off

in the displayer. When the  LIGHT on is 

set,the icon      will be displayed and the 
indicator light in the displayer will be on.
When the LIGHT off is set, the icon      will

be displayed and the indicator light in the

displayer will be off.

Light button

LIGHT

SLEEP

Sleep button

Remote control

BLOW

FAN

AUTO

OPER

HEALTH

AIR

FILTER

TURBO

ON/OFF

BLOW

HOUR

HUMIDITY

ON/OFF

MODE

FAN

BLOW

TURBO

TEMP

TIMER

SLEEP

LIGHT

8

Operation of  remote control

Summary of Contents for KSIB018-H2161

Page 1: ...KSIB018 H2161 KSIB024 H2161...

Page 2: ......

Page 3: ...atment is necessary Thank you for choosing Klimaire air conditioner please read this owner s manual carefully before operating the unit and keep it carefully for consulation The products in this manua...

Page 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Page 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Page 6: ...changer when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Air conditioner absorbs heat from outdoor and transmits...

Page 7: ...outdoor temperature for cooling unit is 10 48 for cooling and heating unit is 15 48 Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdo...

Page 8: ...the actual product Names and functions of each part Indoor unit Air out Outdoor unit Wireless remote control Air in Remote control Front panel Filter Guide louver Wall pipe Bind tape Drainage pipe Rec...

Page 9: ...by 1 When press button the setting temp will be decreased by 1 The temp will be changed quickly the button continuously and setting temp range is by pressing Operation of remote control Swing up and...

Page 10: ...button once again to quit it press this key once again to fix the time NOTE This Remote control is universal it could be used formany units some buttons of this control which are not available to this...

Page 11: ...able In sleep mode setting temperature is adjusted automatically NOTE This remote control is universal it could be used formany units some buttons of this control which are not available to this unit...

Page 12: ...SLEEP button set the sleep mode 2 Press TIMER button then press button to set the 3 Press light button to control displayer light on or off 4 Press Blow button to set Blow function on or off 5 Press...

Page 13: ...control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Sketch map for changing batteries NOTE Fig 1 Fig 2 About lock About AU...

Page 14: ...ight off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this si...

Page 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Page 16: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Page 17: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Page 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Page 19: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Page 20: ...contained in the air Place where a sulfured gas such as the hot spring zones is generated Other place with special circumstance Indoor Unit Installation Position Selection The air inlet and outlet ve...

Page 21: ...National Criterion 4 The user power must offer the reliable earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places th...

Page 22: ...e Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A The dimensions of the space necessary for correct ins...

Page 23: ...a circle the included angle between the evaporator and level should be 0 or more that is good for condensing water drainage 2 Fix the rear panel on the wall with screws Where is pre covered with plas...

Page 24: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Page 25: ...be fixec by the screw Otherwise it can cause a fire or short circuit caused by water or dust 3 4 5 1 2 Disassemble the handle on the outdoor unit right side plate Take off cord anchorage Connect and f...

Page 26: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Page 27: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Page 28: ...66129905212...

Reviews: