background image

17

1.

2.

Select a position where the condensing water can be easily drained out, and the place
is easily connected for outdoor unit.

4.

Can select the place where is strong enough to withstand the full weight and vibration of
the unit. And will not increase the noise.

5.

6.

7.

8.

Make sure that the indoor unit installation should accord with installation dimension 

diagram requirements. 

3.

Select a location where the children can not reach.

1.

The unit installation work must be done by qualified personnel according to the local

rules and this manual.

2.

Before installating, please contact with local authorized maintenance center, if unit is

not installed by the authorized maintenance center, the malfunction may not solved,

due to discommodious contacts.

3.

W

4.

the appliance must be  positioned so that the plug is accessible.

hen removing the unit to the other place, please firstly contact with the authorized

Maintenance Center in the local area.

Notices for installation

Important Notices

Basic Requirements For Installation Position

Install in the following place may cause malfunction. If it is unavoidable contact with 
service center please:

Place where strong heat sources, vapors, flammable gas or volatile object are emitted.

Place where high-frequency waves are generated by radio equipment, welders and 
medical equipment.

Place where a lot of salinities such as coast exists.

Place where the oil (machine oil) is contained in the air.

Place where a sulfured gas such as the hot spring zones is generated.

Other place with special circumstance.

Indoor Unit Installation Position Selection

The air inlet and outlet vent should be far from the obstruction, make sure that the air
can be blown through the whole room.

Be sure to leave enough space to allow access for routine maintenance. The height of the
installed location should be 250cm or more from the floor.

Select a place about 1m or more away from TVset or any other electric appliances.

Select a place where the filter can be easily taken out.

.

Do not use the unit in the immediate surroundings of a laundry a bath a shower or a

swimming pool.

9

1.

Select a location from which noise and outflow air emitted by unit will not inconvenience

   neighbors, animals, plants.

2.

Select a location where there should be sufficient ventilation.

3.

Select a location where there should be no obstructions cover the inlet and outlet vent.

4.

The location should be able to withstand the full weight and vibration of the outdoor unit

     and permit safe installation.

5.

Select a dry place, but do not expose under the direct sunlight or strong wind.

6.

7.

8.
9.

Outdoor Unit Installation Position Selection

Make sure that the outdoor unit installation dimension should accord with installation 
dimension diagram, convenient for maintenance, repair.

The height difference of connecting the tubing within 5m, the length of connecting the
tubing within 10m.

Select a place where it is out of reach for the children.

Select a place where will not block the passage and do not influence the city appearance.

Summary of Contents for KSIB018-H2161

Page 1: ...KSIB018 H2161 KSIB024 H2161...

Page 2: ......

Page 3: ...atment is necessary Thank you for choosing Klimaire air conditioner please read this owner s manual carefully before operating the unit and keep it carefully for consulation The products in this manua...

Page 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Page 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Page 6: ...changer when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Air conditioner absorbs heat from outdoor and transmits...

Page 7: ...outdoor temperature for cooling unit is 10 48 for cooling and heating unit is 15 48 Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdo...

Page 8: ...the actual product Names and functions of each part Indoor unit Air out Outdoor unit Wireless remote control Air in Remote control Front panel Filter Guide louver Wall pipe Bind tape Drainage pipe Rec...

Page 9: ...by 1 When press button the setting temp will be decreased by 1 The temp will be changed quickly the button continuously and setting temp range is by pressing Operation of remote control Swing up and...

Page 10: ...button once again to quit it press this key once again to fix the time NOTE This Remote control is universal it could be used formany units some buttons of this control which are not available to this...

Page 11: ...able In sleep mode setting temperature is adjusted automatically NOTE This remote control is universal it could be used formany units some buttons of this control which are not available to this unit...

Page 12: ...SLEEP button set the sleep mode 2 Press TIMER button then press button to set the 3 Press light button to control displayer light on or off 4 Press Blow button to set Blow function on or off 5 Press...

Page 13: ...control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Sketch map for changing batteries NOTE Fig 1 Fig 2 About lock About AU...

Page 14: ...ight off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this si...

Page 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Page 16: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Page 17: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Page 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Page 19: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Page 20: ...contained in the air Place where a sulfured gas such as the hot spring zones is generated Other place with special circumstance Indoor Unit Installation Position Selection The air inlet and outlet ve...

Page 21: ...National Criterion 4 The user power must offer the reliable earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places th...

Page 22: ...e Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A The dimensions of the space necessary for correct ins...

Page 23: ...a circle the included angle between the evaporator and level should be 0 or more that is good for condensing water drainage 2 Fix the rear panel on the wall with screws Where is pre covered with plas...

Page 24: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Page 25: ...be fixec by the screw Otherwise it can cause a fire or short circuit caused by water or dust 3 4 5 1 2 Disassemble the handle on the outdoor unit right side plate Take off cord anchorage Connect and f...

Page 26: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Page 27: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Page 28: ...66129905212...

Reviews: