Klimaire KSIB009-H2161 Owner'S Manual Download Page 21

Note:

Make sure that the Live wire or Zero line as well as the earth wire in the family power 
socket can not be wrong connected, there should be reliable and no short circuit in the 
diagram.

wrong connection may cause fire.

4. The min. distance from the unit and combustive surface is 1.5m. 

1. The power supply should be used the rated voltage and AC exclusive circuit,

the power cable diameter should be satisfied.

2.

Don't drag the power cable emphatically.

3.

①             ②        

③             

 ④

1. Air conditioner is type 

I

 electric appliance, thus please do conduct reliable earthing

measure.

2. The yellow-green two-color wire in air conditioner is earthing wire and cannot be used

for other propose. It cannot be cut off and be fix it by screw, otherwise it would cause
electric shock.

3. The earth resistance should accord to the National Criterion.

4. The user power must offer the reliable earthing terminal. Please don't connect the

earthing wire with the following place:

Tap water pipe.

Gas pipe.

Contamination pipe.

Other places that professional personnel consider them unreliable.

5. The appliance shall be installed in accordance with national wiring regulations. 

An all-pole disconnection switch having a contact separation of at least 3mm in all poles 

should be connected in fixed wiring. 

It should be reliably earthed, and it should be connected to the special earth device,

the installation work should be operated by the professional. 

The air switch must have the functions of magnetic tripping and heat tripping, in  order 

to  protect  the  short  circuit  and  overloading.

6.

5

. The model and rating values for fuses according the silk print on fuse cover or related 

    PCB board.

Notices for installation

Safety Requirements For Electric Appliances

Earthing requirements

1.

Select a location from which noise and outflow air emitted by unit will not inconvenience

     neighbors, animals, plants.

2.

Select a location where there should be sufficient ventilation.

3.

Select a location where there should be no obstructions cover the inlet and outlet vent.

4.

The location should be able to withstand the full weight and vibration of the outdoor unit

     and permit safe installation.

5.

Select a dry place, but do not expose under the direct sunlight or strong wind.

6.

7.

8.
9.

Outdoor Unit Installation Position Selection

Make sure that the outdoor unit installation dimension should accord with installation 
dimension diagram, convenient for maintenance, repair.

The height difference of connecting the tubing within 5m, the length of connecting the
tubing within 10m.

Select a place where it is out of reach for the children.

Select a place where will not block the passage and do not influence the city appearance.

18

Summary of Contents for KSIB009-H2161

Page 1: ...KSIB009 H2161 KSIB012 H2161...

Page 2: ......

Page 3: ...ion of such waste separately for special treatment is necessary Thank you for choosing Klimaire air conditioner please read this owner s manual carefully before operating the unit and keep it carefull...

Page 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Page 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Page 6: ...y will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low termperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Page 7: ...utdoor temperature for cooling unit is 10 48 for cooling and heating unit is 15 48 Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdoo...

Page 8: ...Run Dry SET TEMP ON OFF ON OFF 5 Names and functions of each part Indoor unit Air in Air out Air out Outdoor unit Wireless remote control Air in Remote control Front panel Filter Guide louver Wall pip...

Page 9: ...Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available Press this button Auto Low Middle High spe...

Page 10: ...time the Blow function is turned off After powered on Blow OFF is defaulted When operating the ON OFF button or switching mode to Cool or Dehumidifying mode the Blow function will keep the original st...

Page 11: ...ased 1 minute Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant...

Page 12: ...EP button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on 3 Press LIGHT button to control the on and off of the displaying part of the unit This function may be not a...

Page 13: ...function If the unit is under defrost mode dual eight position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press butto...

Page 14: ...ight off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this si...

Page 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Page 16: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Page 17: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Page 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Page 19: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Page 20: ...or installation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where...

Page 21: ...connected in fixed wiring It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch must have th...

Page 22: ...ll Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above Above The dimensions of the...

Page 23: ...orator and level should be 0 or more that is good for condensing water drainage 2 Fix the rear panel on the wall with screws Where is pre covered with plastic granula 3 Be sure that the rear panel has...

Page 24: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Page 25: ...and fix power connect cord and signal control wire to terminal block Fix the power connection cable with cord anchorage for cooling and heating unit use the cord anchorage to fix the power connection...

Page 26: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Page 27: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Page 28: ...66129905211...

Reviews: