Klimaire KSIB009-H2161 Owner'S Manual Download Page 11

OFF

This is an universal use remote controller. If 

remote controller sends the following three

kinds of status that the swing status of main
unit will be:

 

When the guide louver start to swing up and

down,  if turn off the Swing, the air guide louver

will stop at current position.

which indicates the guide louver swings up

and down between that all five positions.

 

Press this button, to set up swing angle,

which circularly changes as below:

Press this button, to set up swing angle,

which circularly changes as below:

SWING UP AND DOWN BUTTON

TIMER ON

TIMER ON BUTTON

Timer On setting: Signal “ON” will blink 
and display, signal      will conceal, the 
numerical section will become the timer 
on setting status. During 5 seconds blink, 
by pressing 

 or 

 button to adjust the 

time value of numerical section, every 
press of that button, the value will be 
increased or decreased 1 minute. Hold 
pressing 

 or 

button, 2 seconds later, 

it quickly change, the way of change is: 
During the initial 2.5 seconds, ten numbers 
change in the one place of minute, then 
the one place is constant, ten numbers 
change in the tens place of minute at 2.5 
seconds speed and carry. During 5s blink, 
press the Timer button, the timer setting 
succeeds. The Timer On has been set up, 
repress the timer 

On 

button, the Timer 

On 

will be canceled. Before setting the 

Timer, please adjust the Clock to the  
current actual time.

TIMER OFF  BUTTON

Once

 press this key to enter into 

TIMER OFF setup, in which case

the TIMER OFF icon will blink. 

The method of setting is the same 

TIMER OFF

as for TIMER ON.

Remote control

Names and functions of wireless remote control

Operation of wireless remote control

with multifunction; For some  function, which the model dosen't have, if press the
corresponding button on the remote controller that the unit will keep the original

running status.

Notice: This is a general use remote controller, it could be used  for  the air conditioners

Summary of Contents for KSIB009-H2161

Page 1: ...KSIB009 H2161 KSIB012 H2161...

Page 2: ......

Page 3: ...ion of such waste separately for special treatment is necessary Thank you for choosing Klimaire air conditioner please read this owner s manual carefully before operating the unit and keep it carefull...

Page 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Page 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Page 6: ...y will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low termperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Page 7: ...utdoor temperature for cooling unit is 10 48 for cooling and heating unit is 15 48 Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdoo...

Page 8: ...Run Dry SET TEMP ON OFF ON OFF 5 Names and functions of each part Indoor unit Air in Air out Air out Outdoor unit Wireless remote control Air in Remote control Front panel Filter Guide louver Wall pip...

Page 9: ...Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available Press this button Auto Low Middle High spe...

Page 10: ...time the Blow function is turned off After powered on Blow OFF is defaulted When operating the ON OFF button or switching mode to Cool or Dehumidifying mode the Blow function will keep the original st...

Page 11: ...ased 1 minute Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant...

Page 12: ...EP button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on 3 Press LIGHT button to control the on and off of the displaying part of the unit This function may be not a...

Page 13: ...function If the unit is under defrost mode dual eight position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press butto...

Page 14: ...ight off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this si...

Page 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Page 16: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Page 17: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Page 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Page 19: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Page 20: ...or installation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where...

Page 21: ...connected in fixed wiring It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch must have th...

Page 22: ...ll Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above Above The dimensions of the...

Page 23: ...orator and level should be 0 or more that is good for condensing water drainage 2 Fix the rear panel on the wall with screws Where is pre covered with plastic granula 3 Be sure that the rear panel has...

Page 24: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Page 25: ...and fix power connect cord and signal control wire to terminal block Fix the power connection cable with cord anchorage for cooling and heating unit use the cord anchorage to fix the power connection...

Page 26: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Page 27: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Page 28: ...66129905211...

Reviews: