Press +and - buttons simultaneously to lock or unlock the keyboard. If the remote controller 

is locked, the icon

flicker for three times. If the keyboard is unlocked, the mark will disappear. 

1. Press swing up and down button continuously more than 2s,the main unit will swing back 

and forth from up to down, and then loosen the button, the unit will stop swinging and present 
position of guide louver will be kept immediately.

2. Under swing up and down mode, when the status is switched from off to     , if press this

button again 2s later,     status will switch to off status directly; if press this button again 

within 2s,the change of swing status will also depend on the circulation sequence stated above. 

About switch between Fahrenheit and Centigrade

Under status of unit off, press 

MODE 

and - buttons simultaneously to switch

℃ 

and

 

It indicates: after starting this function by remote controller and the unit has been under 
defrost status, If turn off the unit by remote controller, the unit will not stop defrosting until 
it is finished; if change setting mode by remote controller, the function ,which is set last 
time, won't be carried out until defrosting finished.

Operation of this function on or off: If remote controller is under off status, press mode button 

and blow     

button simultaneously in order to enter or cancel this new function. If the unit is under 

defrost mode, dual eight position on remote controller will display H1.If switch to heat mode,
the position will display H1, which flickers for 5s, in which case, press  +/- button, H1 will 
disappear and  setting temp. be displayed. 

After remote controller is powered  on, the new defrost function will be defaulted to be closed. 

About swing up and down

About lock

About new function of defrosting 

        will be displayed on it, in which case, press any button, the mark will

Operation of wireless remote control

1.

   

Changing batteries and notices

.

.

3.


Slightly to press the place with   

 

  , along the arrowhead direction to push the back cover of wireless 

 

remote  

control. (As show in figure)

Take out the old batteries. (As show in figure)

 Insert two new AAA1.5V dry batteries, and pay attention to the polarity. 
 (As show in figure)

 Attach the back cover of wireless remote control. (As show in figure)

When changing the batteries, do not use the old or different batteries,  

If the wireless remote control will not be used for a long time, please 

otherwise, it can cause the malfunction of the wireless remote control.

take them out, and don't let the leakage liquid damage the wireless 

remote control.

The operation should be in its receiving range.

It should be placed at where is 1m away from the TV set or stereo sound sets.

If the wireless remote control can

 

not operate normally, please take them out, 

 after 30s later and reinsert, if they cannot normally run, please change them.

Sketch map for 
changing batteries

NOTE:

Fig.1

Fig.2

10

Summary of Contents for KSIB009-H2161

Page 1: ...KSIB009 H2161 KSIB012 H2161...

Page 2: ......

Page 3: ...ion of such waste separately for special treatment is necessary Thank you for choosing Klimaire air conditioner please read this owner s manual carefully before operating the unit and keep it carefull...

Page 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Page 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Page 6: ...y will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low termperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Page 7: ...utdoor temperature for cooling unit is 10 48 for cooling and heating unit is 15 48 Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdoo...

Page 8: ...Run Dry SET TEMP ON OFF ON OFF 5 Names and functions of each part Indoor unit Air in Air out Air out Outdoor unit Wireless remote control Air in Remote control Front panel Filter Guide louver Wall pip...

Page 9: ...Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available Press this button Auto Low Middle High spe...

Page 10: ...time the Blow function is turned off After powered on Blow OFF is defaulted When operating the ON OFF button or switching mode to Cool or Dehumidifying mode the Blow function will keep the original st...

Page 11: ...ased 1 minute Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant...

Page 12: ...EP button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on 3 Press LIGHT button to control the on and off of the displaying part of the unit This function may be not a...

Page 13: ...function If the unit is under defrost mode dual eight position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press butto...

Page 14: ...ight off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this si...

Page 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Page 16: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Page 17: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Page 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Page 19: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Page 20: ...or installation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where...

Page 21: ...connected in fixed wiring It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch must have th...

Page 22: ...ll Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above Above The dimensions of the...

Page 23: ...orator and level should be 0 or more that is good for condensing water drainage 2 Fix the rear panel on the wall with screws Where is pre covered with plastic granula 3 Be sure that the rear panel has...

Page 24: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Page 25: ...and fix power connect cord and signal control wire to terminal block Fix the power connection cable with cord anchorage for cooling and heating unit use the cord anchorage to fix the power connection...

Page 26: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Page 27: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Page 28: ...66129905211...