![Klimaire HM700 Series Installation Instructions Manual Download Page 5](http://html1.mh-extra.com/html/klimaire/hm700-series/hm700-series_installation-instructions-manual_1977833005.webp)
HM700A1000
Fig. 2. Typical HM700 Installation.
Measurements in inches (mm).
SIZING
IMPORTANT
The HM700 should only be installed if it has been
sized properly.
Do not use square feet when sizing
a humidifier installation.
Instead, cubic feet must
be used, since the humidity is filling a volume of
space (width x length x height). Also, take into
consideration the
n
tightness
o
of a home
m
s
construction.
The HM700 produces 11 gallons per day (GPD) when run on
120 V and 22 GPD when run on 240 V. See Figure 16 for
details on configuring the HM700 to run on a different voltage.
Table 3 contains AHRI recommendations for humidity
requirements and Table 4 shows what humidifiers and output
configuration will satisfy the humidification requirements.
Table 3. AHRI Recommended Humidity (in gallons per day).
348-32%0
6,91
,91
'
2%
%4
+J
6J
2%
,1
3** 32
238):'322)'8-327,3;2
)<8)62%0
1
1-2-191,)-+,8
7'6);7
1-2-191
13928-2+
78)%1
(-786-&98-32
'3286307
4091&-2+
)0)'86-'%0
1-2-191
Construction
Type
8,000 ft
3
12,000 ft
3
16,000 ft
3
20,000 ft
3
24,000 ft
3
28,000 ft
3
32,000 ft
3
Tight
3.3
4.3
5.4
7.5
9.6
11.7
16
Average
7.6
9.6
11.8
16
20.3
24.4
33
Loose
11.7
14.9
18.1
24.5
30.8
37.1
50