HM700A1000
ELECTRICAL
CAUTION
Wiring to be performed by a licensed electrician. This unit must be installed on a GFI Circuit.
CAUTION
Equipment Damage Hazard
Failure to wire the humidifier in accordance with the wiring instructions could cause permanent damage.
Such errors will void the warranty.
WARNING
HM700A Humidifier must be installed using a dedicated 15 amp circuit breaker and hardwired directly to comply
with UL product listing. All wiring must be done per governing electrical codes.
Electrical line cord plugs can overheat and result in risk of damage to property and/or personal injury. Note: Product
warranty will be voided if these instructions are not followed.
CAUTION
JUMPER WIRE INSTALLATION
p
DO NOT install mains voltage wire (hot or neutral) into 120 or 240 terminal.
p
DO install mains wires into L1 terminal (hot) and P terminal (hot/neutral).
p
DO install jumper from P to 120 or 240 terminal (according to mains voltage).
Installation Steps
1.
Unit requires a dedicated circuit with GFI protection. Bring circuit to a disconnect near the device to protect from electrical
shock when servicing.
2.
Hard wire humidifier to disconnect according as shown at right.
3.
Install factory-supplied jumper between the P terminal and the terminal that corresponds to supply voltage.
4.
Remove green wire attached to case body and drain valve (remove canister for access).
5.
Clip ground wire as close to drain valve as possible and remove excess.
1
:%'
0
2%
4
:%'
.YQTIV
0
2%
4
.YQTIV
:%'
0
2%
4
:%'
.YQTIV
0
2%
4
.YQTIV
1