4. Continuity
Apo
A-HOLD
Apo
A-HOLD
Apo
A-HOLD
• Press the “
Ω
/ ” button to select
continuity. The “ ” symbol will appear
in the LCD.
• Buzzer sounds and RED indication light
illuminates if reading is less than 25 Ω.
• Power the unit OFF by holding the “ V ”
or “
Ω
/ ” button for one second.
WARRANTY
www.kleintools.com/warranty
CLEANING AND STORAGE
Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use
abrasive cleaners or solvents.
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high
temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in
the Specifications section, allow the instrument to return to normal operating conditions before using it.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed of in
accordance with local regulations.
CUSTOMER SERVICE
Resistance Measurement (Ohms)
Range
Resolution Accuracy
0 to 399
0.1Ω
± (0.8% + 4 digits)
0.4k to 4kΩ 0.001KΩ
Overload Protection:
600V
Continuity Test
Overload
Protection
Open Circuit
Voltage
Tone
600V
Appx. 0.44V
< 25Ω
AC Voltage Measurement
Range
Resolution Accuracy
1 to 399.9 0.1V
± (1.2% + 5 digits)
400 to 599 1V
600 to 750 1V
± (1.2% + 8 digits)
Overload Protection:
750V
Frequency:
50 to 60 Hz
Input Impedance:
>10MΩ
Response:
Averaging
DC Voltage Measurement
Range
Resolution Accuracy
± 1 to 399.9 0.1V
± (0.5% + 3 digits)
± 400 to 599 1V
± 600 to 750 1V
± (0.5% + 5 digits)
Overload Protection:
750V
Input Impedance:
>10M
Ω
ELECTRICAL SPECIFICATIONS
RED LEAD
RED LEAD
BLACK LEAD
BLACK LEAD