background image

 

 

 

 

 
USER'S 
MANUAL 

 

BM061s 

BM062s 
BM063s 

BM065s 

 
Compact AC/DC 
Clamp-on 
Multimeter Series 

 

 

Summary of Contents for 102088

Page 1: ...USER S MANUAL BM061s BM062s BM063s BM065s Compact AC DC Clamp on Multimeter Series ...

Page 2: ... OVERVOLTAGE CATEGORY II is energy consuming equipment to be supplied from the fixed installation Note Examples include household office and laboratory appliances OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed inst...

Page 3: ... test lead provided with the equipment or UL Listed Probe Assembly with same rating or better This Clamp on meter is designed to apply around or remove from uninsulated hazardous live conductors But still individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible CAUTION Disconnect the test leads from the test...

Page 4: ...eter during measurement 3 Push buttons for special functions features 4 Input Jack for all functions EXCEPT non invasive ACA DCA current functions 5 Common Ground reference Input Jack for all functions EXCEPT non invasive ACA DCA current functions 6 Slide switch Selector to turn the power ON OFF and Select a function 7 3 3 4 digits 4000 counts LCD display 8 Jaw trigger for opening the clamp jaw 9 ...

Page 5: ...odels 061s 062s separate ACV DCV slide switch positions are being used Press the Hz button momentarily to activate Hz Frequency The Hz trigger level is determined by the selected function range from where the Hz function is activated In ACV function activating the Hz function during significant measurements can get the most appropriate trigger level to avoid electrical noises in most cases Electri...

Page 6: ...t condition ACA DCA Current clamp on function Inputs are made through the clamp jaws for non invasive ACA DCA current measurements CAUTION Application and removal of the Clamp on meter Press the jaw trigger and clamp the jaws around only one single conductor of a circuit for load current measurement Make sure the jaws are completely closed or else it will introduce measurement errors Enclosing mor...

Page 7: ...rmers motors and conductor wires will affect measurement accuracy Keep the jaws away from them as much as possible to minimize influence CAUTION Do not measure above rated frequency 400Hz In measuring above rated frequency the magnetic circuits may reach to a hazardous temperature Resistance and Continuity functions CAUTION Using Resistance Continuity or Diode function in a live circuit will produ...

Page 8: ...tive A zero reading indicates a shorted diode defective An OL indicates an open diode defective Reverse the test leads connections reverse biased across the diode The digital display shows OL if the diode is good Any other readings indicate the diode is resistive or shorted defective Capacitance function Inputs are made through the test leads terminals Slide switch on defaults at Press SELECT butt...

Page 9: ...rily to select degree F Fahrenheit You can also use a plug adapter Bkb32 Optional purchase with banana pins to type K socket to adapt other type K standard mini plug temperature probes HOLD The Hold feature freezes the display for later viewing Press the HOLD button momentarily to toggle to the Hold feature The annunciator turns on MAX The max feature compares and displays the measured maximum val...

Page 10: ...er to sleep mode automatically after approximately 30 minutes of neither slide switch nor push button operations to extend battery life To wake up the meter from APO press any push button momentarily or set the slide switch to the OFF position and then slide back on again Always set the slide switch to the OFF position manually when the meter is not in use 5 MAINTENANCE WARNING To avoid electrical...

Page 11: ...e with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for periods of longer than 60 days remove the batteries and store them separately Battery replacement The meter uses standard 1 5V AAA Size NEDA 24G or IEC R03 battery X 2 or 1 5V AAA Size NEDA 24A or IEC LR03 alkaline battery X 2 Loosen the 2 captive screws from the battery cover case Lift the b...

Page 12: ... Category III 600 Volts ac dc Transient protection 6 5kV 1 2 50 s surge for all models Pollution degree 2 E M C Meets EN61326 1 2006 EN55022 EN61000 3 2 EN61000 3 3 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 In an RF field of 3V m Capacitance function is not specified Other function ranges Total Accuracy Specified Accuracy 50igits Performance above 3V m is...

Page 13: ...m 5 to 100 of range or otherwise specified Maximum Crest Factor are as specified below and with frequency spectrums besides fundamentals fall within the meter specified AC bandwidth for non sinusoidal waveforms Fundamentals are specified at 50Hz and 60Hz DC Voltage RANGE Accuracy 400 0 mV 0 3 3d 4 000V 40 00V 400 0V 0 5 3d 600V 1 0 4d Input Impedance 10M 30pF nominal 1000M for 400 0mV range AC Vol...

Page 14: ...nF 5 000 F 50 00 F 500 0 F 3000 F 3 5 6d 1 Additional 50 00nF range accuracy is not specified 2 Accuracies with film capacitor or better 3 Specified with battery voltage above 2 8V approximately half full battery Accuracy decreases gradually to 12 at low battery warning voltage of approximately 2 4V DCA Current Clamp on RANGE Accuracy1 2 400 0A 0A 50 0A 1 0 4d 50 0A 200 0A 1 5 5d 200 0A 300 0A 2 0...

Page 15: ... 065s Crest Factor 1 8 1 at full scale 3 6 1 at half scale Hz Frequency Function Sensitivity Sine wave Range 400 0mV 350mV 10Hz 1kHz 4 000V 3 2V 5Hz 20kHz 40 00V 25V 5Hz 100kHz 400 0V 100V 5Hz 100kHz 600V 410V 5Hz 5kHz DCA ACA Unspecified Display counts 5000 Maximum resolution 0 001Hz Accuracy 0 5 4d Type K Temperature Model 063s 065s only RANGE Accuracy 20 oC 300 oC 2 0 3d 300 oC 537 oC 3 0 3d 4 ...

Page 16: ...repaid to BRYMEN TECHNOLOGY CORPORATION BRYMEN assumes no risk for damage in transit BRYMEN will at its option repair or replace the defective product free of charge However if BRYMEN determines that the failure was caused by misused altered neglected or damaged by accident or abnormal conditions of operation or handling you will be billed for the repair THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU O...

Reviews: