G
as
C
onnection
Statutory requirements
This installation must conform with the following:
■ Manufacturer’s Installation instructions
■ Local Gas Fitting Regulations
■ Municipal Building Codes
■ Refer to AS/NZS 5601.1 for Gas Installations
■
AS/NZS 3000 - Wiring Rules
■ Local Electrical Regulations
■ Any other statutory regulations
Preparing to install
Refer to AS/NZS 5601.1 for piping size details. These built-in cooktops are intended to
be inserted in a benchtop cutout. Only an officially authorised technician should
connect the appliance. Before you begin, turn off the gas and electricity supply.
A full operational test and a test for possible leakages must
be carried out by the fitter after installation.
Access to the whole length of the connection hose must be
possible and the gas hose
must be replaced before the end of its
service life
(indicated on the hose).
Before Leaving
-
Check all connections for gas leaks with soap
and water.
Check for satisfactory operation of the ignition system
on all burners both individually and combined.
DO NOT use a naked flame for detecting leaks. Ignite all burners
both individually and concurrently to ensure correct operation
of gas valves, burners and ignition. Turn gas taps to low flame
position and observe stability of the flame for each burner
individually and all together. Adhere the duplicate data plate to
an accessible location near the hotplate. When satisfied with the
hotplate, please instruct the user on the
correct method of
operation. In case the appliance fails to operate
correctly after all
checks have been carried out, refer to the authorised service
provider in your area.
WARNING: THE BURNER FLAME MUST BE ADJUSTED BY THE
INSTALLER. FAULTY INSTALLATION IS NOT COVERED BY THE
MANUFACTURER’S WARRANTY.
LPG gas connection
Natural gas connection
115
115
pressure test point
pressure test point
LPG CONVERSION -
REGULATOR
20