PRESSURE SWITCH. When the pressure reaches the calibrated value of the pressure switch, the
switch closes the fill solenoid valve and signals the end of the filling to the timer. At this point, the
dishwasher is ready to start the wash cycle.
Water level in tank for each load:
•
From 3- 3.3 litres (version with alternating) to 4 – 4.5 litres
Safety level:
9 to 10 litres (if a turbine is fitted: 7.8 litres)
NOTE: If the TURBINE malfunctions, the electronic timer display shows the error E7. This
error is temporary and can be reset by the customer who is thus aware (instruction manual)
that the appliance is operating with an incorrect amount of water. The appliance will thus
signal error E7 at the end of each wash, leaving the decision whether or not to call the
technical assistance service to the customer.
MORE DETAILED INFORMATION ON THE DIAGNOSTIC CODES OF THE ELECTRONIC
TIMERS IS AVAILABLE IN THE SERVICE MANUALS OF THE RELATIVE TIMERS.
TURBINE CONTROL:
1- TURBINE FLOW METER
4- TUB
7- RESINS
2- AIRBREAK
5- AIR TRAPS
8- SALT
3- WASH WATER LEVEL
6- WATER SOFTENER
9- TRAY