Installation & Operation Manual:
Automated Forklift Entryway Sanitizing System
_________________________________________________________________________________________________
10 |
P a g e
location of the pumping module, Lay the remaining cable next to the pumping module
and advance to the nozzle locations.
Figure 8
8.
Find the positions on the body of the vehicle that will allow the nozzles to point to the tire
tread with at least a 2 to 3 inch spacing. If the nozzle is located too close to the tire it will
not cover the entire tread surface area. If it is located too far away from the tire it will
spray wider than the tire tread surface area and waste sanitizer. Affix the nozzles for all
three or four tires, depending on the lift. Have an assistant turn the steering through the
complete range of motion while you observe and ensure clearance with the nozzles. Pay
attention to anything that might contact the nozzles. Relocate the nozzles if necessary.
Figure 9
NOTE:
The kit comes with nozzle assemblies set for each side of the forklift, (2) left and
(2) right. If required, you may remove the clamp from the nozzle assembly and reverse if