Instruction
manual
HK
12/2
page
18
__________________________________________________________________________
Attention
Hydraulic oils can cause cutaneous eruption (eczema) or other health
hazards. Avoid longer skin contact. Wash your hands carefully after each
contact.
5.6. Storage and transport of the crimping tool
In order to protect the pump unit against damages it has to be cleaned carefully after heavy
duty operations.
The hydraulic pump is supplied with a hook (Pos.-No. 2) to hold the pump lever down for
easier transportation. The hydraulic hose (Pos.-No. 7) is the most vulnerable part of the
pump and has to be handled with care. The minimum bending radius should not be lower
than 70 mm.
5.7. Reference as to which spare parts can be exchanged by the customer
Within the determined use of the tool only the dies (Pos.-No. 6) and the oil are permitted to
be changed by the customer.
Attention
Do not damage the seals of the tool.
Do not attempt to repair the tool yourself, and do not remove any parts such as screws and
other components.
6. Troubleshooting
a.) If the pump doesn’t reach the final operating pressure air may have penetrated the
system.
=>
Hold the working unit lower than the pump and actuate the pump lever (Pos.-
No 1) until the dies are completely closed. Repeat this procedure 2 or 3 times.
If the pump is still not reaching the full pressure repeat this process again until the
pump works properly.
Should the malfunction not be corrected by this the pump must be returned to the
manufacturer.
b.) The pump loses oil.
=>
Return the pump to the manufacturer. Do not open or destroy the seal of the pump.