HE.14138_A © 09/2011
6
AHP 700-L
GB
Instruction Manual Battery-hydraulic Pump
authorised
copy
4. Remarks in respect of the determined use
The pump can be transported and operated in any position.
Attention
In combination with a 2 m high-pressure hose it is not possible to work in a cable trench. For this application
at least a 3 m high-pressure hose is needed.
4.1 Operation of the unit
1. The female coupling of the hydraulic hose HSOEL2 (pic. 23.4) must be connected to the male coupling (pic. 1.5) of
the pump (pic. 1.6).
2. Select the right working unit for the intended application.
3. The selected working unit will be connected via the hydraulic hose HSOEL2 (pic. 23.4) with the pump (pic. 16)
Attention
Do not operate the pump without a working unit.
Attention
Before starting to operate the pump the oil level must be checked and possibly adjusted. (pic. 13 - 15).
4. Besides the built-in trigger (pic. 1.11) the following accessories can be connected:
• Remote control HTA4 (pic. 23.2)
• Safety foot switch incl. 4m cable FTA4 (pic. 24.3)
• Two hand safety control ZST4 (pic. 24.4)
The pump recognises the various accessories through a special coding; the built-in trigger (pic. 1.11) will be deacti-
vated accordingly.
5. The battery and possibly the spare battery will be plugged into the sockets (see pic. 12).
6. The pump is now ready to operate. The LCD display (pic. 1.9) is activated.
7. Select the program for the intended application by turning the selection knob (pic. 1.8) or the data function.
8. The working cycle (s. pic. 17ff.) is initiated by activating the advance function of the ‚forward and return keys‘
(pic. 1.11)
Attention
The retraction button of the forward and return keys (pic 1.11) is always activ and can be actuated at any time
and any program.