Problem
Possible Cause
Prevention / Solution
Burner will not light using
ignitor.
Gas issues:
Trying to light wrong
burner.
See the instructions for lighting
the grill in the “Operation”
section.
Burner not engaged with
control valve.
Make sure valves are
positioned inside of burner
tubes.
Obstruction in burner.
Ensure burner tubes are not
obstructed with spider webs or
other matted, see “Cleaning
and Maintenance”section.
No gas flow.
Make sure the gas cylinder
not empty, refer to “Sudden
drop in gas flow” (below).
Vapour lock at coupling
nut to gas cylinder.
Turn control knobs to “OFF”
and disconnect coupling nut
from gas cylinder. Reconnect
and retry.
Coupling nut ad gas
cylinder valve not fully
connected.
Turn the coupling nut
approximately onehalf to
three-quarters.